Omnipod
POD
Pump integration for Omnipod, requires RileyLink (with at least 2.0 firmware) device.
pref_omnipod_beep_bolus_enabled
pref_omnipod_beep_basal_enabled
pref_omnipod_beep_smb_enabled
pref_omnipod_beep_tbr_enabled
pref_omnipod_pod_debugging_options_enabled
pref_omnipod_timechange_enabled
Bolus Beep Enabled
Basal Beep Enabled
SMB Beep Enabled
TBR Beep Enabled
Pod Debugging Options Enabled
DST/Timezone Detection Enabled
Moments ago
Pod Mgmt
Pod Status
%1$.2f U left
Over 50 U
Pod Address
Pod Expires
Warning
No Pod connected
Pod setup in progress (Pod progress status: %1$s)
Pod not initialized
Pod Fault
Pod Fault: %1$s %2$s
Pod running (last delivery status: %1$s)
Active Pod Alerts
Ack Alerts
%1$.2f %2$s (%3$s)
Initializing
Active
Unknown
Omnipod (433.91 MHz)
RileyLink Address invalid.
Operation is not possible.\n\nYou need to configure Omnipod first, before you can use this operation.
Operation is not possible.\n\n You need to wait few minutes, until AAPS tries to set profile for first time.
Illegal PodInitActionType: %1$s
No active pod.
Command verification failed.
An unexpected error occurred. Please report! (type: %1$s).
Communication failed: received invalid input parameters.
Communication failed: timeout.
Communication failed: an unexpected error occurred. Please report!
Communication failed: message integrity verification failed.
Communication failed: received an invalid packet from the Pod.
Communication failed: the Pod is in a wrong state.
Communication failed: received an invalid response from the Pod.
Communication failed: received a message with an invalid sequence number from the Pod.
Communication failed: received a message with an invalid address from the Pod.
Communication failed: failed to decode message from the Pod.
Communication failed: nonce resync failed.
Communication failed: nonce out of sync.
Communication failed: not enough data received from the Pod.
A Pod fault (%1$03d %2$s) has been detected. Please deactivate your Pod and start a new one.
Communication failed: the Pod returned an error response.
Pod Management
Init Pod
Deactivate Pod
Reset Pod
Pod History
Set Bolus
Cancel Bolus
Set Temporary Basal
Cancel Temporary Basal (Internally by driver)
Cancel Temporary Basal (Forced by user)
Set Basal Schedule
Get Pod Status
Get Pod Info
Set Time
Configure Alerts
Acknowledge Alerts
Suspend Delivery
Resume Delivery
Unknown Entry
%1$.1f U
%1$.1f U, CH=%2$.1f g
Rate: %1$.1f U, Duration: %2$d min
If you press OK, the Pod state will be forcibly reset and you will not be able to communicate with the Pod anymore. Do this only if you can not communicate with the Pod anymore. If you can still communicate with the Pod, please use the Deactivate Pod option.
Pod History not available at the moment.
Fill the Pod
\nFill the new Pod with enough insulin for 3 days.\n\nListen for two beeps from the Pod during the filling process. These indicate that the minimum amount of 85U has been inserted. Be sure to completely empty the fill syringe, even after hearing the two beeps.\n\nAfter filling the Pod, please press Next.\n\nNote: do not remove the Pod\'s needle cap at this time.
Priming
Trying to pair with the new Pod and prime it.\n\nWhen all items are checked, you can press Next.\n\nNote: please keep the Pod and the RileyLink a few inches apart at this time.
Attach the Pod
\nPrepare the infusion site. Remove the Pod\'s needle cap and adhesive backing and attach the Pod to the infusion site.\n\nIf the cannula sticks out, please press Cancel and discard your Pod.\n\nPress Next to insert the cannula and begin basal delivery.
Inserting cannula
Trying to set initial basal schedule and insert the cannula.\n\nWhen all items are checked, you can press Next.
Pod Info
\nThe Pod is now active.\n\nYour basal schedule has been programmed and the cannula has been inserted.\n\nPlease verify that the cannula has been inserted correctly and replace your Pod if you feel hasn\'t.
Deactivate Pod
\nPress Next to deactivate the Pod.\n\nNote: This will suspend all insulin delivery and deactivate the Pod.
Deactivating the Pod
Deactivating the Pod.\n\nWhen all items are checked, you can press Next.\n\nNote: If deactivating continuously fails, please press Cancel and use the Reset Pod option to forcibly reset the Pod state.
Pod deactivated.\n\nPlease remove the Pod from your body and discard it.
Pair Pod
Prime Pod
Fill Cannula
Set Basal Profile
Cancel Delivery
Deactivate Pod
Omnipod Dash
DASH
Pump integration for Omnipod Dash.
Finish pairing reminder
Finish setup reminder
Pod will expire soon
Pod will expire soon
Shutdown is imminent
Low reservoir
Unknown alert
Setting basal profile might have failed. Delivery might be suspended! Please refresh Pod status.
Setting temp basal might have failed. If there was a temp basal already running, that may have been cancelled! Please refresh pod status.
Setting time might have failed. Delivery might be suspended! Please refresh Pod status.
Unable to verify whether the bolus succeeded. Please verify that your Pod is bolusing or cancel the bolus.
RL Stats
Pulse Log
LOT
TID
Firmware version
PM %1$s / PI %2$s
Errors
Basal profile is the same, so it will not be set again.
Reset RileyLink Config
Time and/or Timezone change on pump
%1$s and %2$s
%1$s ago
Waiting for RileyLink connection...
- %1$d minute
- %1$d minutes
- %1$d hour
- %1$d hours
- %1$d day
- %1$d days