Omnipod Pod Pump integration for Omnipod, requires RileyLink (with at least 2.0 firmware) device. AAPS.Omnipod.bolus_beeps_enabled AAPS.Omnipod.basal_beeps_enabled AAPS.Omnipod.smb_beeps_enabled AAPS.Omnipod.tbr_beeps_enabled AAPS.Omnipod.suspend_delivery_button_enabled AAPS.Omnipod.pulse_log_button_enabled AAPS.Omnipod.time_change_enabled AAPS.Omnipod.expiration_reminder_enabled AAPS.Omnipod.expiration_reminder_hours_before_shutdown AAPS.Omnipod.low_reservoir_alert_enabled AAPS.Omnipod.low_reservoir_alert_units Bolus beeps enabled Basal beeps enabled SMB beeps enabled TBR beeps enabled Suspend Delivery button enabled Pulse Log button enabled DST/Time zone detection enabled Expiration reminder enabled Hours before shutdown Low reservoir alert enabled Number of units Moments ago Pod mgmt Pod status Total delivered %1$.2f U %1$.2f U left Over 50 U Pod address Pod expires Warning No active Pod Setup in progress (waiting for pair and prime) Setup in progress (waiting for cannula insertion) Running Suspended Pod fault Activation time exceeded Inactive Pod fault: %1$s %2$s Active Pod alerts Ack alerts %1$.2f %2$s (%3$s) %1$.2fU/h @%2$s (%3$d/%4$d minutes) Omnipod (433.91 MHz) RileyLink address invalid. Operation is not possible.\n\nYou need to configure Omnipod first, before you can use this operation. Operation is not possible.\n\n You need to wait a few minutes, until AAPS tries to set basal profile for first time. Illegal PodInitActionType: %1$s No active Pod Command verification failed An unexpected error occurred. Please report! (%1$s: %2$s). Communication failed: received invalid input parameters Communication failed: timeout Communication failed: an unexpected error occurred. Please report! Communication failed: message integrity verification failed Communication failed: received an invalid packet from the Pod Communication failed: the Pod is in a wrong state Communication failed: received an invalid response from the Pod Communication failed: received a message with an invalid sequence number from the Pod Communication failed: received a message with an invalid address from the Pod Communication failed: failed to decode message from the Pod Communication failed: nonce resync failed Communication failed: nonce out of sync Communication failed: not enough data received from the Pod A Pod fault (%1$03d %2$s) has been detected. Please deactivate your Pod and start a new one Communication failed: the Pod returned an error response Pod management Init Pod Deactivate Pod Discard Pod Pod history Set bolus Cancel bolus Set temporary basal Cancel temporary basal (internally by driver) Cancel temporary basal Set basal schedule Get Pod status Get Pod info Set time Configure alerts Acknowledge alerts Suspend delivery Resume delivery Unknown entry %1$.2f U %1$.2f U, CH=%2$.1f g Rate: %1$.2f U, duration: %2$d min If you press OK, the Pod state will be forcibly reset and you will not be able to communicate with the Pod anymore. Do this only if you can not communicate with the Pod anymore. If you can still communicate with the Pod, please use the Deactivate Pod option.\n\nIf you wish to proceed, please make sure to also remove the Pod from your body. Pod History not available at the moment. Fill the Pod \nFill the new Pod with enough insulin for 3 days.\n\nListen for two beeps from the Pod during the filling process. These indicate that the minimum amount of 85U has been inserted. Be sure to completely empty the fill syringe, even after hearing the two beeps.\n\nAfter filling the Pod, please press Next.\n\nNote: do not remove the Pod\'s needle cap at this time.\nNote: please place the RileyLink in an upright position and place the Pod a few inches away. Priming Trying to pair with the new Pod and prime it.\n\nWhen all items are checked, you can press Next.\n\nNote: please place the RileyLink in an upright position and place the Pod a few inches away it. Attach the Pod \nPrepare the infusion site. Remove the Pod\'s needle cap and adhesive backing and attach the Pod to the infusion site.\n\nIf the cannula sticks out, please press Cancel and discard your Pod.\n\nPress Next to insert the cannula and begin basal delivery. Inserting cannula Trying to set initial basal schedule and insert the cannula.\n\nWhen all items are checked, you can press Next. Pod info \nThe Pod is now active.\n\nYour basal schedule has been programmed and the cannula has been inserted.\n\nPlease verify that the cannula has been inserted correctly and replace your Pod if you feel hasn\'t. Deactivate Pod \nPress Next to deactivate the Pod.\n\nNote: This will suspend all insulin delivery and deactivate the Pod. Deactivating the Pod Deactivating the Pod.\n\nWhen all items are checked, you can press Next.\n\nNote: If deactivating continuously fails, please press Cancel and use the Discard Pod option to forcibly reset the Pod state. Pod deactivated.\n\nPlease remove the Pod from your body and discard it. Pair Pod Prime Pod Fill cannula Set basal profile Cancel delivery Deactivate Pod Finish pairing reminder Finish setup reminder Pod will expire soon Pod will expire soon Shutdown is imminent Low reservoir Unknown alert Setting basal profile failed. Delivery might be suspended! Please manually refresh the Pod status from the Omnipod tab and resume delivery if needed. Setting basal profile might have failed. Delivery might be suspended! Please manually refresh the Pod status from the Omnipod tab and resume delivery if needed. Setting basal profile failed. Delivery is suspended! Please manually resume delivery from the Omnipod tab. Cancelling temp basal might have failed. Please manually refresh the Pod status from the Omnipod tab. Setting temp basal failed. If a temp basal was previously running, it might have been cancelled. Please manually refresh the Pod status from the Omnipod tab. Setting temp might have basal failed. If a temp basal was previously running, it has been cancelled. Please manually refresh the Pod status from the Omnipod tab. Setting time might have failed. Delivery might be suspended! Please manually refresh the Pod status from the Omnipod tab and resume delivery if needed. Setting time failed. Delivery is suspended! Please manually resume delivery from the Omnipod tab. Unable to verify whether the bolus succeeded. Please manually verify that your Pod is bolusing by listening to clicks. If you are sure that the bolus didn\'t succeed, you should manually delete the bolus entry from Treatments, even if you click \'Cancel bolus\' now! Unable to verify whether SMB bolus (%1$.2f U) succeeded. If you are sure that the Bolus didn\'t succeed, you should manually delete the SMB entry from Treatments. RL stats Pulse log LOT TID Firmware version PM %1$s / PI %2$s Errors Basal profile is the same, so it will not be set again. Reset RileyLink config Time and/or time zone changed on the Pod %1$s and %2$s %1$s ago Waiting for RileyLink connection... Bolus did not succeed Refresh Resume delivery Pod suspended Less than a minute ago Suspend Pair and prime Fill cannula and set basal profile Get pulse log Uncertain failure Cancelled the old temporary basal, but failed to set new temporary basal Set fake temporary basal because the Pod is suspended Cancel fake temporary basal that was created because the Pod was suspended uncertain Alert configuration updated in Pod RileyLink Other Alerts Confirmation beeps Exit Previous Next Finish Description Source Date Type: Failed to set basal profile: received an empty profile. Make sure to activate your basal profile. No basal profile is active. Make sure to activate your basal profile. %1$d minute %1$d minutes %1$d hour %1$d hours %1$d day %1$d days