Treatments safety
Max allowed bolus [U]
Max allowed carbs [g]
Preferences
Refresh treatments from NS
Reset Databases
Do you really want to reset the databases?
Exit
Use extended boluses for >200%
DanaR Bluetooth device
Always use basal absolute values
Please reboot your phone or restart AndroidAPS from the System Settings \notherwise Android APS will not have logging (important to track and verify that the algorithms are working correctly)!
Some buttons to quickly access common features
Enter advanced log book entries.
Used for configuring the active plugins
Learning program
Displays the food presets defined in Nightscout
Insulin preset for Humalog and NovoRapid / NovoLog
Insulin preset for Fiasp
Allows you to define the peak of the insulin activity and should only be used by advanced users
Activate or deactivate the implementation triggering the loop.
Synchronizes your data with Nightscout
State of the algorithm in 2016
State of the algorithm in 2017
Most recent algorithm for advanced users
Displays the current state of your loop and buttons for most common actions
Shows an ongoing notification with a short overview of what your loop is doing
Define a profile which is offline available.
Provides the profile you have defined in Nightscout
Define a profile with only one time block.
Pump integration for Accu-Chek Combo pumps, requires having ruffy installed
Pump integration for DANA Diabecare R pumps
Pump integration for domestic DANA Diabecare R pumps
Pump integration for DANA Diabecare R pumps with upgraded firmware
Pump integration for DANA Diabecare RS pumps
Pump integration for Accu-Chek Insight pumps, requires having SightRemote installed
Pump integration for people who do multiple daily injections for their diabetes therapy
Pump integration for pumps which don\'t have any driver yet (Open Loop)
Sensitivity is calculated the same way like Oref0, but you can specify timeframe to the past. Minimal carb absorption is calculated from max carb absorption time from preferences.
Sensitivity is calculated from 24h data in the past and carbs (if not absorbed) are cut after time specified in preferences.
Sensitivity is calculated from 8h data in the past and carbs (if not absorbed) are cut after time specified in preferences. Plugin also calculates UAM.
Sensitivity is calculated as a weighted average from deviations. Newer deviations have higher weight. Minimal carb absorption is calculated from max carb absorption time from preferences. This algorithm is the fastest in following sensitivity changes.
Receive BG values from the patched Dexcom G5 app.
Receive BG values from Glimp.
Receive BG values from the 600SeriesAndroidUploader.
Downloads BG data from Nightscout
Receive BG values from xDrip.
Saves all treatments that were made
Monitor and control AndroidAPS using your WearOS watch.
Show information about your loop on your xDrip+ watchface.
Remote control AndroidAPS using SMS commands.
Start
Verify
Units
DIA
IC
ISF
Basal
Target
NO PROFILE SET
Insulin:
Carbs:
IOB:
IOB:
Activity:
Total IOB:
Total IOB activity:
Dur:
Ratio:
Ins:
IOB:
Total IOB:
Insulin
Carbs
BG
TT
Carbs
Corr
U
Bolus IOB
Run now
VIRTUAL PUMP
Base basal rate
Temp basal
Extended bolus
Battery
Reservoir
OK
Last run
Input parameters
Glucose status
Current temp
IOB data
Profile
Meal data
Result
No glucose data available
No change requested
Request
Rate
Duration
Reason
Glucose
Delta
Delta:
Config Builder
Objectives
OpenAPS MA
Overview
NS Profile
Simple profile
TempBasal
Treatments
Virtual Pump
Careportal
Pump
Which pump would you like to use with AndroidAPS?
Treatments
Which plugin should be used for treatment handling?
Profile
Which profile should AndroidAPS use?
APS
Which APS algorithm should make therapy adjustments?
General
These are some general plugins you might find useful.
Which constraints are applied?
days
Constraints
Loop
Loop
Use this to activate AndroidAPS\' loop integration.
APS
After processed constraints
Temp basal set by pump
Last enacted
OK
Cancel
NO APS SELECTED OR PROVIDED RESULT
Safety
Plugin is disabled
Constraints violation
Bolus delivery error
Tempbasal delivery error
Basal value [%]
% (100% = current)
Accept new temp basal:
Treatment
Calculator
Constraint applied!
Confirmation
Enter new treatment:
Bolus
Bolus:
Basal
Basal:
Carbs
Change your input!
Set new extended bolus:
BG Source
Where should AndroidAPS gain it\'s data from?
xDrip
APS Mode
Closed Loop
Open Loop
Loop Disabled
Disable loop
Enable loop
New suggestion available
Unsupported version of NSClient
Unsupported version of Nightscout
NSClient not installed. Record lost!
BG available in NS
Pump status available in NS
Manual enacts
LOOP DISABLED BY CONSTRAINTS
Czech
English
Basal IOB
Bolus constraint applied
Carbs constraint applied
BG Check
Announcement
Note
Question
Exercise
Pump Site Change
CGM Sensor Insert
CGM Sensor Start
Insulin Cartridge Change
Profile Switch
Snack Bolus
Meal Bolus
Correction Bolus
Combo Bolus
Temp Basal Start
Temp Basal End
Carbs correction
OpenAPS Offline
Event type
Other
Meter
Sensor
Carbs
Insulin
Carb time
Split
Duration
Percent
Absolute
Notes
Event time
Profile
Entered By
Glucose type
No profile loaded from NS yet
TempBasal
Extended Bolus
Nightscout version:
Missing
Preferences exported
Export settings to
Import settings from
Settings imported
File not found
Export settings
Import settings
Dutch
German
Spanish
Greek
Italian
Romanian
Russian
Swedish
French
Chinese
Polski
Max U/hr a Temp Basal can be set to
This value is called max basal in OpenAPS context
Maximum basal IOB OpenAPS can deliver [U]
This value is called Max IOB in OpenAPS context\nThis is maximal insulin in [U] APS can deliver at once.
Bulgarian
DISMISS
Language
DanaR
Connecting
Connected
Disconnected
DanaR pump settings
End User License Agreement
MUST NOT BE USED TO MAKE MEDICAL DECISIONS. THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION.
I UNDERSTAND AND AGREE
Save
No bluetooth adapter found
Selected device not found
Pump connection error
Pump IOB
Daily units
Last bolus
%.1fh ago
Invalid input data
Value not set properly
Reload profile
View profile
Enacted
Comment
Success
Percent
Absolute
Cancel temp basal
SMS Communicator
Waiting for result
Allowed phone numbers
+XXXXXXXXXX;+YYYYYYYYYY
To deliver bolus %1$.2fU reply with code %2$s
To send calibration %1$.2f reply with code %2$s
Bolus failed
Bolus %.2fU delivered successfully
Going to deliver %.2fU
Bolus %.2fU delivered successfully
Delivering %.2fU
Allow remote commands via SMS
Remote bolus not allowed
Finger
Sensor
Manual
Temporary Target
Temporary Target Cancel
DanaR profile settings
DIA [h]
Duration of Insulin Activity
Failed to update basal profile
Reload
Uploading
E bolus
DS bolus
DE bolus
error
refill
basal hour
glucose
carbohydrate
alarm
Total %d records uploaded
S bolus
Alarms
Basal Hours
Boluses
Carbohydrates
Daily insulin
Errors
Glucose
Refill
Suspend
Connecting for %d s
Pump password
Wrong pump password!
Pump is busy
Delivered
Stopped
Bolus stopped
Stopping bolus
Occlusion
Stop
STOP PRESSED
Waiting for pump
Going to deliver %.2fU
Setting up visualization and monitoring, and analyzing basals and ratios
Verify that BG is available in Nightscout, and pump insulin data is being uploaded
Starting on an open loop
Run in Open Loop mode for a few days and manually enact lots of temp basals. Set up and use temporary and default temporary targets (e.g. for activity or hypo treatment carbs)
Understanding your open loop, including its temp basal recommendations
Based on that experience, decide what max basal should be, and set it on the pump and preferences
Starting to close the loop with Low Glucose Suspend
Run in closed loop with max IOB = 0 for a few days without too many LGS events
Tuning the closed loop, raising max IOB above 0 and gradually lowering BG targets
Run for a few days, and at least one night with no low BG alarms, before dropping BG
Adjust basals and ratios if needed, and then enable auto-sens
1 week successful daytime looping with regular carb entry
Enabling additional features for daytime use, such as advanced meal assist
Enabling additional features for daytime use, such as SMB
You must read the wiki and rise maxIOB to get SMBs working fine! A good start is maxIOB=average mealbolus + 3 x max daily basal
You reached allowed limit
No profile selected
Loop has been disabled
Loop has been enabled
Loop is disabled
Loop is enabled
%1$.2f limited to %2$.2f
Value %s is out of hard limits
Remote basal setting is not allowed
Remote command is not allowed
To start basal %1$.2fU/h reply with code %2$s
To suspend loop for %1$d minutes reply with code %2$s
Temp basal %1$.2fU/h for %2$d min started successfully
Temp basal start failed
To stop temp basal reply with code %s
Temp basal canceled
Canceling temp basal failed
Uknown command or wrong reply
QuickWizard
QuickWizard settings
Button text:
Carbs:
Valid:
Add
Edit
Remove
Meal
Corr
Korean
Actions
AndroidAPS started
NS upload only (disabled sync)
NS upload only. Not effective on SGV unless a local source like xDrip is selected. Not effective on Profiles while NS-Profiles is used.
Pump not initialized!
Pump not initialized, profile not set!
Prime/Fill
Please make sure the amount matches the specification of your infusion set!
Other
Fill/Prime standard insulin amounts.
Button 1
Button 2
Button 3
Units:
mg/dl
mmol/l
DIA:
Target range:
Range for Visualization
High and low mark for the charts in Overview and Smartwatch
LOW mark
HIGH mark
Wear
Resend All Data
Open Settings on Wear
Pump Error
Low Battery
Pump Shutdown
Pump Battery Discharged
DanaR Korean
Basal rate:
Setting of basal profile failed
Basal profile in pump updated
Disable EasyUI mode in pump
Enable extended boluses on pump
Change mode from U/d to U/h on pump
Basal value below minimum. Profile not set!
BG:
Last BG:
MDI
MM640g
Ongoing Notification
OLD DATA
%d min ago
%dmin ago
Local Profile
OpenAPS AMA
Short avg. delta
Long avg. delta
Array of %d elements.\nActual value:
Autosens data
Script debug
Use AMA autosens feature
Refresh events from NS
Delete treatments in the future
Eating Soon
Hypo
Activity
Remove record:
DanaR Stats
Cumulative TDD
Exponentially Weighted TDD
Basal
Bolus
TDD
Date
Ratio
# Days
Weight
Possibly inaccurate if using boluses for priming/filling!
Old Data Please Press "RELOAD"
Total Base Basal
TBB * 2
Initializing ...
ACT
CONF
LOOP
SP
OAPS
LP
DANA
HOME
VPUMP
NSPROFILE
TREAT
CP
OBJ
WEAR
SMS
Shorten tab titles
Always use short average delta instead of simple delta
Useful when data from unfiltered sources like xDrip gets noisy.
Advanced Settings
Model: %1$02X Protocol: %2$02X Code: %3$02X
Profile
Default value: 3 This is a key OpenAPS safety cap. What this does is limit your basals to be 3x (in this people) your biggest basal rate. You likely will not need to change this, but you should be aware that’s what is discussed about “3x max daily; 4x current” for safety caps.
Default value: 4 This is the other half of the key OpenAPS safety caps, and the other half of “3x max daily; 4x current” of the safety caps. This means your basal, regardless of max basal set on your pump, cannot be any higher than this number times the current level of your basal. This is to prevent people from getting into dangerous territory by setting excessively high max basals before understanding how the algorithm works. Again, the default is 4x; most people will never need to adjust this and are instead more likely to need to adjust other settings if they feel like they are “running into” this safety cap.
autosens_max
Default value: 1.2\nThis is a multiplier cap for autosens (and soon autotune) to set a 20% max limit on how high the autosens ratio can be, which in turn determines how high autosens can adjust basals, how low it can adjust ISF, and how low it can set the BG target.
autosens_min
Default value: 0.7\nThe other side of the autosens safety limits, putting a cap on how low autosens can adjust basals, and how high it can adjust ISF and BG targets.
autosens_adjust_targets
Autosens adjust targets too
Default value: true\nThis is used to allow autosens to adjust BG targets, in addition to ISF and basals.
bolussnooze_dia_divisor
Default value: 2\nBolus snooze is enacted after you do a meal bolus, so the loop won’t counteract with low temps when you’ve just eaten. The example here and default is 2; so a 3 hour DIA means that bolus snooze will be gradually phased out over 1.5 hours (3DIA/2).
min_5m_carbimpact
Default value: 3.0 This is a setting for default carb absorption impact per 5 minutes. The default is an expected 3mg/dl/5min. This affects how fast COB are decayed, and how much carb absorption is assumed in calculating future predicted BG, when BG is falling more than expected, or not rising as much as expected.
Attention!\nNormally you do not have to change these values below. Please CLICK HERE and READ the text and make sure you UNDERSTAND it before change any of these values.
http://openaps.readthedocs.io/en/latest/docs/walkthrough/phase-3/beyond-low-glucose-suspend.html
Only numeric digits are allowed.
Only numeric digits within the range %1$s - %2$s are allowed.
The field must not be empty
Phone number not valid
Invalid SMS phone number
Copy To Clipboard
Copied to clipboard
Show log
Calibration
Send calibration %.1f to xDrip?
xDrip+ not installed
Calibration sent to xDrip
Remote calibration not allowed
Calibration sent. Receiving must be enabled in xDrip.
xDrip is not receiving calibrations
Pump suspended
Getting pump status
Setting temp basal
Stopping temp basal
Setting extended bolus
Stopping extended bolus
Updating basal rates
Disconnecting
Executing
Virtual pump settings
Upload status to NS
Wrong password
Password for settings
Unlock settings
Approaching insulin daily limit
NSClient
NSCI
URL:
Autoscroll
Restart
NSClient
Nightscout URL
Enter Your Nightscout URL
NS API secret
NS API secret
Enter NS API secret (min 12 chars)
Deliver now
Clear queue
Show queue
Queue:
Status:
Paused
nsclientinternal_url
nsclientinternal_api_secret
danar_bt_name
danar_password
danar_useextended
danar_visualizeextendedaspercentage"
danarprofile_dia
Clear log
nsclientinternal_autoscroll
nsclientinternal_paused
NSCLIENT has no write permission. Wrong API secret?
Wear settings
Show detailed IOB
Break down IOB into bolus and basal IOB on the watchface
not successful - please check phone
Not available
smscommunicator_allowednumbers
smscommunicator_remotecommandsallowed
Patient age
Child
Teenage
Adult
Insulin resistant adult
age
child
teenage
adult
resistantadult
Please select patient age to setup safety limits
I_understand
Glimp
%s needs battery optimalization whitelisting for proper performance
Loop suspended
Suspended (%d m)
Superbolus (%d m)
Suspend loop for 1h
Suspend loop for 2h
Suspend loop for 3h
Suspend loop for 10 h
Disconnect pump for 15 min
Disconnect pump for 30 min
Disconnect pump for 1 h
Disconnect pump for 2 h
Disconnect pump for 3 h
Resume
Wrong duration
Loop suspended
Loop resumed
15min trend
COB
Superbolus
Log app start to NS
ns_logappstartedevent
Exiting application to apply settings.
DanaRv2
Insulin
Which type of insulin are you using?
Fast Acting Insulin
Novorapid, Novolog, Humalog
Fiasp
INS
key_usersuperbolus
Enable superbolus in wizard
Enable superbolus functionality in wizard. Do not enable until you learn what it really does. IT MAY CAUSE INSULIN OVERDOSE IF USED BLINDLY!
IOB
COB
Firmware
Last connection
Bluetooth status
About
Missing SMS permission
xDrip Status (watch)
xDrip Statusline (watch)
xds
Show BGI
Add BGI to status line
No upload to NS
All data sent to NS are dropped. AAPS is connected to NS but no change in NS is done
ns_upload_only
ns_noupload
Basal Step
Bolus Step
ExtendedBolus
TempTarget
Cancel Extended Bolus
Sensor age
Canula age
Insulin age
hours
Basal type
Invalid profile !!!
ProfileSwitch
Pump battery age
Pump Battery Change
Alarm options
nsalarm_urgent_high
nsalarm_high
nsalarm_low
nsalarm_urgent_low
nsalarm_staledata
nsalarm_urgent_staledata
nsalarm_staledatavalue
nsalarm_urgent_staledatavalue
Urgent high
High
Low
Urgent low
Stale data
Urgent stale data
Stale data threshold [min]
Urgent stale data threshold [min]
Interval for autosens [h]
Amount of hours in the past for sensitivity detection (carbs absorption time is excluded)
openapsama_autosens_period
nsclient_localbroadcasts
Pump
OpenAPS
Uploader
Sensitivity detection
Which sensitivity algorithm should be used?
SENS
Sensitivity Oref0
Sensitivity Oref1
Sensitivity AAPS
Absorption settings
absorption_maxtime
absorption_cutoff
Meal max absorption time [h]
Time in hours where is expected all carbs from meal will be absorbed
rangetodisplay
Visualize extended bolus as %
SAGE
IAGE
CAGE
PBAGE
OAPS
UPLD
BAS
EXT
Keep screen on
Prevent Android to turn screen off. It will consume lot of energy when not plugged to power outlet.
By turning on Autosense feature remember to enter all eated carbs. Otherwise carbs deviations will be identified wrong as sensitivity change !!
Sensitivity WeightedAverage
OK
Cancel
Not all profiles loaded!
Values not stored!
Accu-Chek Combo
COMBO
Enable broadcasts to other apps (like xDrip).
Enable local Broadcasts.
ACTIVITY & FEEDBACK
CARBS & BOLUS
CGM & OPENAPS
PUMP
Basal value [U/h]
Duration [min]
OpenAPS SMB
SMB
use_smb
use_uam
Enable UAM
Enable SMB
Use Super Micro Boluses instead of temp basal for faster action
Detection of Unannounced meals
insulin_oref_peak
IOB Curve Peak Time
Peak Time [min]
Free-Peak Oref
Rapid-Acting Oref
Ultra-Rapid Oref
DIA of %1$f too short - using %2$f instead!
Activate profile
Date
INVALID
Waiting for pairing on pump
Paring OK
Paring timed out
PAIRING
danars_paring_key_
danars_address
danars_name
No device found so far
Empty reservoir
Blood sugar measurement alert
Remaining insulin level
DanaRS
Dana
Selected pump
Pair new pump
Bolus speed
danars_bolusspeed
Set basal step to 0.01 U/h
Serial number
wizard_include_cob
wizard_include_trend_bg
Percentage
Time shift
Default Temp-Targets
eatingsoon duration
eatingsoon target
activity duration
activity target
hypo duration
hypo target
eatingsoon_duration
eatingsoon_target
activity_duration
activity_target
hypo_duration
hypo_target
Prime
Getting extended bolus status
Getting bolus status
Getting temporary basal status
Getting pump settings
Getting pump time
reuse
Controls from Watch
Set Temp-Targets and enter Treatments from the watch.
Connection timed out
Food
g
m
h
]]>
kJ
En
Pr
Fat
]]>
Waiting for bolus end. Remaining %d sec.
Processing event
Starting bolus delivery
Command is executed right now
Pump driver corrected
Pump unreachable
Missed BG readings
raise_urgent_alarms_as_android_notification
Use system notifications for alerts and notifications
enable_pump_unreachable_alert
enable_missed_bg_readings
Local alerts
Alert if no BG data is received
Alert if pump is unreachable
Pump unreachable threshold [min]
pump_unreachable_threshold
missed_bg_readings_threshold
Urgent Alarm
INFO
bt_watchdog
bt_watchdog_last
Bluetooth
BT Watchdog
Switches off the phone\'s bluetooth for one second if no connection to the pump is possible. This may help on some phones where the bluetooth stack freezes.
DexcomG5 App (patched)
Upload BG data to NS
dexcomg5_nsupload
G5 upload settings
Poctech upload settings
Show detailed delta
Show delta with one more decimal place
45 60 75 90 105 120
Max minutes of basal to limit SMB to
Unsupported pump firmware
Send BG data to xDrip+
dexcomg5_xdripupload
In xDrip+ select 640g/Eversense data source
NSClient BG
Basal value replaced by minimal supported value
Basal value replaced by maximum supported value
BG calculation
Bolus IOB calculation
Basal IOB calculation
Trend calculation
Superbolus calculation
Yes
No
Positive only
Negative only
COB calculation
Temporary target calculation
Loop enabled
APS selected
NSClient has write permission
Closed mode enabled
Maximal IOB set properly
BG available from selected source
Basal values not aligned to hours: %s
Invalid profile: %s
Programming pump for bolusing
Refresh
State
Activity
No connection for %d min
%1$d%% (%2$d min remaining)
%1$.1f %2$s (%3$s)
Initializing
Suspended due to error
Suspended by user
Running
Cancelling TBR
Setting TBR (%1$d%% / %2$d min)
Bolusing (%.1f U)
Refreshing
Requested operation not supported by pump
Unsafe usage: extended or multiwave boluses are active. Loop mode has been set to low-suspend only 6 hours. Only normal boluses are supported in loop mode
Unsafe usage: the pump uses a different basal rate profile than the first. The loop has been disabled. Select the first profile on the pump and refresh.
A bolus with the same amount was requested within the last two minutes. To prevent accidental double boluses and to guard against bugs this is disallowed.
Now
Reading pump history
pump history
Setting basal profile
Pump cartridge level is low
Pump battery is low
The pump is showing the error E%1$d: %2$s
Low
Empty
Normal
Pump clock update needed
Warning
TBR CANCELLED warning was confirmed
The pump could not be reached. No bolus was given
Bolus delivery failed. It appears no bolus was delivered. To be sure, please check the pump to avoid a double bolus and then bolus again. To guard against bugs, boluses are not automatically retried.
Only %1$.2f U of the requested bolus of %2$.2f U was delivered due to an error. Please check the pump to verify this and take appropriate actions.
Delivering the bolus and verifying the pump\'s history failed, please check the pump and manually. If a bolus was delivered, it will be added to treatments during the next connection to the pump.
Not enough insulin for bolus left in reservoir
Extended bolus delivery error
Insight
Insight Pump
Status
Changed
PUMP STOPPED
Status Updated
ago
with
Active TBR
min left
Log book
Last Completed Action
min
remaining over
total with
upfront with
Stay always connected
IDLE
SYNCING
BUSY
SYNCED
STARTUP
needs
Not connected to companion app!
Companion app does not appear to be installed!
Incompatible companion app, we need version
Unknown
Waiting for code confirmation
Code rejected
App binding
Not authorized
Incompatible
second
minute
hour
day
week
s
%1$ds expires %2$s
Keep-alive status
Statistics
Connect preemptively
Automatically connect when AndroidAPS screens are opened, before any pump command is requested, to reduce connection delay
Not recommended due to battery drain
enableSMB_always
enableSMB_with_COB
enableSMB_with_temptarget
enableSMB_after_carbs
enableSMB_with_high_temptarget
Enable SMB always
Enable SMB always independently to boluses. Possible only with BG source with nice filtering of data like G5
Enable SMB after carbs
Enable SMB for 6h after carbs, even with 0 COB. Possible only with BG source with nice filtering of data like G5
Enable SMB with COB
Enable SMB when there is COB active.
Enable SMB with temp targets
Enable SMB when there is temp target active (eating soon, exercise)
Enable SMB with high temp targets
Enable SMB when there is high temp target active (exercise)
Let temp basal run
Mute
Insulin
Carbs
Buttons
show_calibration_button
show_cgm_button
show_carbs_button
show_wizard_button
show_insulin_button
show_treatment_button
Sends a calibration to xDrip+ or open G5 calibration dialog
Opens xDrip+, back buttons returns to AAPS
insulin_button_increment_1
insulin_button_increment_2
insulin_button_increment_3
carbs_button_increment_1
carbs_button_increment_2
carbs_button_increment_3
Number of carbs to add when button is pressed
Amount of insulin to add when button is pressed
Could not launch CGM application. Make sure it is installed.
CGM
History browser
Notify on SMB
Show SMB on the watch like a standard bolus.
ns_create_announcements_from_errors
Create announcements from errors
Create Nightscout announcement for error dialogs and local alerts (also viewable in Careportal under Treatments)
G5
Show the predictions on the watchface.
Predictions
Data Choices
Fabric Upload
Allow automated crash reporting and feature usage data to be sent to the developers via the fabric.io service.
Please update your G5 app to supported version
Start Activity TT
Start Eating soon TT
TT
Do not bolus, record only
Category
Subcategory
Bolus will be recorded only
Autobackfill missig BGs from NS
ns_autobackfill
SMB set by pump
Sensitivity
Deviations
Carbs On Board
Insulin On Board
Basals
No action selected, nothing will happen
Start Hypo TT
Running dev version. Closed loop is disabled.
fromNSAreCommingFakedExtendedBoluses
Engineering mode enabled
Engineering mode not enabled and not on release branch
%.2f U/h
Reading basal profile
The pump history has changed after the bolus calculation was performed. The bolus was not delivered. Please recalculate if a bolus is still needed.
Bolus successfully delivered, but adding the treatment entry failed. This can happen if two small boluses of the same size are administered within the last two minutes. Please check the pump history and treatment entries and use the Careportal to add missing entries. Make sure not to add any entries for the exact same minute and same amount.
Rejecting high temp since calculation didn\'t consider recently changed pump history
Refreshing pump state
The basal rate on the pump has changed and will be updated soon
Basal rate changed on pump, but reading it failed
Checking for history changes
Multiple boluses with the same amount within the same minute were just imported. Only one record could be added to treatments. Please check the pump and manually add a bolus record using the Careportal tab. Make sure to create a bolus with a time no other bolus uses.
\n\nhttp://www.androidaps.org\nhttp://www.androidaps.de (de)\n\nfacebook:\nhttp://facebook.androidaps.org\nhttp://facebook.androidaps.de (de)
The last bolus is older than 24 hours or is in the future. Please check the date on the pump is set correctly.
Time/date of the delivered bolus on pump seems wrong, IOB is likely incorrect. Please check pump time/date.
ProfileSwitch missing. Please do a profile switch or press \"Activate Profile\" in the LocalProfile.
Bolus count
TBR count
Objective %d not started
Objective %d not finished
Pump is not temp basal capable
No valid basal rate read from pump
Closed loop mode disabled in preferences
Autosens disabled in preferences
SMB disabled in preferences
Limiting max basal rate to %1$.2f U/h because of %2$s
pump limit
openapsma_max_basal
openapsama_current_basal_safety_multiplier
openapsama_max_daily_safety_multiplier
it must be positive value
max basal multiplier
max daily basal multiplier
openapsma_max_iob
A bolus was delivered within the last 3 minutes, skipping SMB
Basal set correctly
Limiting max percent rate to %1$d%% because of %2$s
treatmentssafety_maxbolus
Limiting bolus to %1$.1f U because of %2$s
Limiting max IOB to %1$.1f U because of %2$s
Limiting carbs to %1$d g because of %2$s
Limiting IOB to %1$.1f U because of %2$s
max value in preferences
hard limit
treatmentssafety_maxcarbs
unsafe usage
openapsama_useautosens
Read status failed
Record pump site change
Record insulin cartridge change
SMB always and after carbs disabled because active BG source doesn\'t support advanced filtering
SMB not allowed in open loop mode
Food
IobCobCalculator
reset
Waiting for time synchronization (%d sec)
Disconnected (%d m)
Automatic careportal events
Automatically upload insulin, cannula and battery changes and pump alarms to Nightscout
openapsmb_max_iob
Maximum total IOB OpenAPS can\'t go over [U]
This value is called Max IOB in OpenAPS context\nOpenAPS will not add more insulin if current IOB is greater than this value
Pump stopped
Pump started
Pump paused
Meal max absorption time [h]
Time at which any meal is considered absorbed. Remaining carbs will be cut off.
Time
show_notes_entry_dialogs
Show notes field in treatment dialogs
SetupWizardActivity
Next
Prev
Setup Wizard
FINISH
Select your language
language
openapsama_min_5m_carbimpact
Asked: %1$.2fU Delivered: %2$.2fU Error code: %3$d
First insulin increment
Second insulin increment
Third insulin increment
First carbs increment
Second carbs increment
Third carbs increment
CGM
ns_wifionly
ns_wifi_ssids
ns_allowroaming
ns_chargingonly
Use WiFi connection only
WiFi SSID
Only if charging
Connection settings
Allowed SSIDs (semicolon separated)
Allow connection in roaming
always_use_shortavg
Max autosens ratio
Min autosens ratio
Bolus snooze dia divisor
Max daily safety multiplier
Current basal safety multiplier
n/a
Autobackfill BG
Irish
Wizard Settings
wearwizard_bg
wearwizard_tt
wearwizard_trend
wearwizard_cob
wearwizard_bolusiob
wearwizard_basaliob
Calculations included in the Wizard result:
Display Settings
General Settings
Enable NSClient
Welcome to setup wizard. It will guide you through the setup process\n
Pump setup
Read status
Changes must be done in NS
Skip setup wizard
Press the button below to enable AndroidAPS to suggest/make basal changes
Press the button below to enable Objectives. Look in the Objectives tab, after you finish this wizard, to make AndroidAPS completely functional.\n
Enable Objectives
Configure APS plugin
startupwizard_processed
Configure Sensitivity plugin
Sensitivity plugin is used for sensitivity detection and COB calculation. For more info visit:
https://github.com/MilosKozak/AndroidAPS/wiki/Sensitivity-detection-and-COB
NSClient handles connection to Nightscout. You can skip this part now but you will not be able to pass objectives until you setup it.
Please remember: new insulin profiles require DIA at least 5h. DIA 5-6h on new profile is equal to DIA 3h on old insulin profiles.
Configure BG source
Please select source of profile. If patient is a child you should use NS profile. If there is nobody following you on Nightscout you will probably prefer Local profile. Please remember that you are only selecting the profile source. To use it you must activate it by executing \"Profile switch\"
Select one from availables algorithms. They are sorted from oldest to newest. Newer algorithm is usually more powerful and more aggresive. Thus if you are new looper you may probably start with AMA and not with latest one. Do not forget to read the OpenAPS documentation and configure it before use.
Start your first objective
Permission
Ask for permission
Application needs location permission for BT scan
Application needs storage permission to be able store log files
Request
Configure Insulin plugin
Exit
User options
Display time format
Button scroll
Beep on button press
Alarm
Sound
Vibrate
Both
LCD on time [s]
Backlight on time [h]
Glucose units
Shutdown(hours)
Low reservoir (Units)
Save options to pump
On
Off
Open navigation
Close navigation
Plugin preferences
Completed, well done!
Not completed yet
Time elapsed
%1$d. Objective
Poctech
Receive BG values from Poctech app
high_temptarget_raises_sensitivity
low_temptarget_lowers_sensitivity
High temptarget raises sensitivity
= 100]]>
Low temptarget lowers sensitivity
Invalid pump setup, check the docs and verify that the Quick Info menu is named QUICK INFO using the 360 configuration software.
Custom
Large Time Difference
Large time difference:\nTime in pump is off by more than 1.5 hours.\nPlease adjust the time manually on the pump and make sure that reading the history from the pump does not cause unexpected behaviour.\nIf possible, remove the history from the pump before changing the time or disable the closed loop for one DIA after the last wrong history entry but minimum one DIA from now.
keep_screen_on
Clean AndroidAPS started
Stored settings found
Attention: If you activate and connect to a hardware pump, AndroidAPS will copy the basal settings from the profile to the pump, overwriting the existing basal rate stored on the pump. Make sure you have the correct basal setting in AndroidAPS. If you are not sure or don\'t want to overwrite the basal settings on your pump, press cancel and repeat switching to the pump at a later time.
Treatment data incomplete
A treatment (insulin: %.2f, carbs: %d, at: %s) could not be added to treatments. Please check and manually add a record as appropriate.
Generated eCarbs with amount: %1$dg, duration: %2$dh, delay: %3$dm
key_plugin_stats_report_timestamp
No autosens data available
- %d day
- %d days
- %d hour
- %d hours
- %d minute
- %d minutes