Treatments safety Max allowed bolus [U] Max allowed carbs [g] Preferences Refresh treatments from NS Reset Databases Do you really want to reset the databases? Exit Use extended boluses for >200% DanaR Bluetooth device Always use basal absolute values Please reboot your phone or restart AndroidAPS from the System Settings \notherwise Android APS will not have logging (important to track and verify that the algorithms are working correctly)! Objective: Gate: Start Verify Units DIA IC ISF Basal Target NO PROFILE SET Insulin: Carbs: IOB: IOB: Activity: Total IOB: Total IOB activity: Dur: Ratio: Ins: IOB: Total IOB: Insulin Carbs BG TT Carbs Corr U Bolus IOB Run now VIRTUAL PUMP Base basal rate Temp basal Extended bolus Battery Reservoir OK Last run Input parameters Glucose status Current temp IOB data Profile Meal data Result No glucose data available No change requested Request Rate Duration Reason Glucose Delta Delta: Config Builder Objectives OpenAPS MA Overview NS Profile Simple profile TempBasal Treatments Virtual Pump Careportal Pump Treatments Profile APS General days Minimal duration Constraints Loop Loop APS After processed constraints Temp basal set by pump Last enacted OK Cancel NO APS SELECTED OR PROVIDED RESULT Safety Plugin is disabled Constraints violation Bolus delivery error Tempbasal delivery error Basal value [%] % (100% = current) Accept new temp basal: Treatment Calculator Constraint applied! Confirmation Enter new treatment: Bolus Bolus: Basal Basal: Carbs Change your input! Set new extended bolus: BG Source xDrip APS Mode Closed Loop Open Loop Loop Disabled Disable loop Enable loop New suggestion available Unsupported version of NSClient Unsupported version of Nightscout NSClient not installed. Record lost! BG available in NS Pump status available in NS Manual enacts LOOP DISABLED BY CONSTRAINTS Czech English Basal IOB Bolus constraint applied Carbs constraint applied BG Check Announcement Note Question Exercise Pump Site Change CGM Sensor Insert CGM Sensor Start Insulin Cartridge Change Profile Switch Snack Bolus Meal Bolus Correction Bolus Combo Bolus Temp Basal Start Temp Basal End Carbs correction OpenAPS Offline Event type Other Meter Sensor Carbs Insulin Carb time Split Duration Percent Absolute Notes Event time Profile Entered By Glucose type No profile loaded from NS yet TempBasal Extended Bolus Nightscout version: Missing Preferences exported Export settings to Import settings from Settings imported File not found Export settings Import settings Dutch German Spanish Greek Italian Romanian Russian Swedish French Chinese Polski Max U/hr a Temp Basal can be set to This value is called max basal in OpenAPS context Maximum basal IOB OpenAPS can deliver [U] This value is called Max IOB in OpenAPS context\nThis is maximal insulin in [U] APS can deliver at once. Bulgarian DISMISS Language DanaR Connecting Connected Disconnected DanaR pump settings Nightscout End User License Agreement MUST NOT BE USED TO MAKE MEDICAL DECISIONS. THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. I UNDERSTAND AND AGREE Save No bluetooth adapter found Selected device not found Pump connection error Pump IOB Daily units Last bolus %.1fh ago Invalid input data Value not set properly Reload profile View profile Enacted Comment Success Percent Absolute Cancel temp basal SMS Communicator Waiting for result Allowed phone numbers +XXXXXXXXXX;+YYYYYYYYYY To deliver bolus %.2fU reply with code %s To send calibration %.2f reply with code %s Bolus failed Bolus %.2fU delivered successfully Going to deliver %.2fU Bolus %.2fU delivered successfully Delivering %.2fU Allow remote commands via SMS Remote bolus not allowed Finger Sensor Manual Temporary Target Temporary Target Cancel DanaR profile settings DIA [h] Duration of Insulin Activity Failed to update basal profile Reload Uploading E bolus DS bolus DE bolus error refill basal hour glucose carbohydrate alarm Total %d records uploaded S bolus Alarms Basal Hours Boluses Carbohydrates Daily insulin Errors Glucose Refill Suspend Connecting for %d s Pump password Wrong pump password! Pump is busy Delivered Stopped Bolus stopped Stopping bolus Occlusion Stop STOP PRESSED Waiting for pump Going to deliver %.2fU Setting up visualization and monitoring, and analyzing basals and ratios Verify that BG is available in Nightscout, and pump insulin data is being uploaded Starting on an open loop Run in Open Loop mode for a few days, and manually enact lots of temp basals Understanding your open loop, including its temp basal recommendations Based on that experience, decide what max basal should be, and set it on the pump and preferences Starting to close the loop with Low Glucose Suspend Run in closed loop with max IOB = 0 for a few days without too many LGS events Tuning the closed loop, raising max IOB above 0 and gradually lowering BG targets Run for a few days, and at least one night with no low BG alarms, before dropping BG Adjust basals and ratios if needed, and then enable auto-sens 1 week successful daytime looping with regular carb entry Enabling additional features for daytime use, such as advanced meal assist Enabling additional features for daytime use, such as SMB You reached allowed limit No profile selected Loop has been disabled Loop has been enabled Loop is disabled Loop is enabled %.2f limited to %.2f Value %s is out of hard limits Remote basal setting is not allowed Remote command is not allowed To start basal %.2fU/h reply with code %s To suspend loop for %d minutes reply with code %s Temp basal %.2fU/h for %d min started successfully Temp basal start failed To stop temp basal reply with code %s Temp basal canceled Canceling temp basal failed Uknown command or wrong reply QuickWizard QuickWizard settings Button text: Carbs: Valid: Add Edit Remove Meal Corr Korean Actions AndroidAPS started NS upload only (disabled sync) NS upload only. Not effective on SGV unless a local source like xDrip is selected. Not effective on Profiles while NS-Profiles is used. Pump not initialized! Pump not initialized, profile not set! Prime/Fill Please make sure the amount matches the specification of your infusion set! Other Fill/Prime standard insulin amounts. Button 1 Button 2 Button 3 Units: mg/dl mmol/l DIA: Target range: Range for Visualization High and low mark for the charts in Overview and Smartwatch LOW mark HIGH mark Wear Resend All Data Open Settings on Wear Pump Error Low Battery Pump Shutdown Pump Battery Discharged DanaR Korean Basal rate: Setting of basal profile failed Basal profile in pump updated Disable EasyUI mode in pump Enable extended boluses on pump Change mode from U/d to U/h on pump Basal value below minimum. Profile not set! BG: Last BG: MDI MM640g Ongoing Notification OLD DATA %d min ago %dmin ago Local Profile OpenAPS AMA Short avg. delta Long avg. delta Array of %d elements.\nActual value: Autosens data Script debug Use AMA autosens feature Refresh events from NS Eating Soon Hypo Activity Remove record: DanaR Stats Cumulative TDD Exponentially Weighted TDD Basal Bolus TDD Date Ratio # Days Weight Possibly inaccurate if using boluses for priming/filling! Old Data Please Press "RELOAD" Total Base Basal TBB * 2 Initializing ... ACT CONF LOOP SP OAPS LP DANA HOME VPUMP NSPROFILE TREAT CP OBJ WEAR SMS Shorten tab titles Always use short average delta instead of simple delta Useful when data from unfiltered sources like xDrip gets noisy. Advanced Settings Model: %02X Protocol: %02X Code: %02X Profile Default value: 3 This is a key OpenAPS safety cap. What this does is limit your basals to be 3x (in this people) your biggest basal rate. You likely will not need to change this, but you should be aware that’s what is discussed about “3x max daily; 4x current” for safety caps. Default value: 4 This is the other half of the key OpenAPS safety caps, and the other half of “3x max daily; 4x current” of the safety caps. This means your basal, regardless of max basal set on your pump, cannot be any higher than this number times the current level of your basal. This is to prevent people from getting into dangerous territory by setting excessively high max basals before understanding how the algorithm works. Again, the default is 4x; most people will never need to adjust this and are instead more likely to need to adjust other settings if they feel like they are “running into” this safety cap. autosens_max Default value: 1.2\nThis is a multiplier cap for autosens (and soon autotune) to set a 20% max limit on how high the autosens ratio can be, which in turn determines how high autosens can adjust basals, how low it can adjust ISF, and how low it can set the BG target. autosens_min Default value: 0.7\nThe other side of the autosens safety limits, putting a cap on how low autosens can adjust basals, and how high it can adjust ISF and BG targets. autosens_adjust_targets Autosens adjust targets too Default value: true\nThis is used to allow autosens to adjust BG targets, in addition to ISF and basals. bolussnooze_dia_divisor Default value: 2\nBolus snooze is enacted after you do a meal bolus, so the loop won’t counteract with low temps when you’ve just eaten. The example here and default is 2; so a 3 hour DIA means that bolus snooze will be gradually phased out over 1.5 hours (3DIA/2). min_5m_carbimpact Default value: 3.0 This is a setting for default carb absorption impact per 5 minutes. The default is an expected 3mg/dl/5min. This affects how fast COB are decayed, and how much carb absorption is assumed in calculating future predicted BG, when BG is falling more than expected, or not rising as much as expected. Attention!\nNormally you do not have to change these values below. Please CLICK HERE and READ the text and make sure you UNDERSTAND it before change any of these values. http://openaps.readthedocs.io/en/latest/docs/walkthrough/phase-3/beyond-low-glucose-suspend.html Only numeric digits are allowed. Only numeric digits within the range %1$s - %2$s are allowed. The field must not be empty Phone number not valid Invalid SMS phone number Copy To Clipboard Copied to clipboard Show log Calibration Calibration Send calibration %.1f to xDrip? xDrip+ not installed Calibration sent to xDrip Remote calibration not allowed Calibration sent. Receiving must be enabled in xDrip. xDrip is not receiving calibrations Pump suspended Getting pump status Setting temp basal Stopping temp basal Setting extended bolus Stopping extended bolus Updating basal rates Disconnecting Executing Virtual pump settings Upload status to NS Wrong password Password for settings Unlock settings Approaching insulin daily limit NSClient NSCI URL: Autoscroll Restart NSClient Nightscout URL Enter Your Nightscout URL NS API secret NS API secret Enter NS API secret (min 12 chars) Deliver now Clear queue Show queue Queue: Status: Paused nsclientinternal_url nsclientinternal_api_secret danar_bt_name danar_password danar_useextended danar_visualizeextendedaspercentage" danarprofile_dia Clear log nsclientinternal_autoscroll nsclientinternal_paused NSCLIENT has no write permission. Wrong API secret? Wear settings Show detailed IOB Break down IOB into bolus and basal IOB on the watchface not successful - please check phone Not available smscommunicator_allowednumbers smscommunicator_remotecommandsallowed Patient age Child Teenage Adult Insulin resistant adult age child teenage adult resistantadult Please select patient age to setup safety limits I_understand Glimp Device does not appear to support battery optimization whitelisting! Please Allow Permission %s needs battery optimalization whitelisting for proper performance Loop suspended Suspended (%d m) Superbolus (%d m) Suspend loop for 1h Suspend loop for 2h Suspend loop for 3h Suspend loop for 10 h Disconnect pump for 15 min Disconnect pump for 30 min Disconnect pump for 1 h Disconnect pump for 2 h Disconnect pump for 3 h Resume Wrong duration Loop suspended Loop resumed 15min trend COB Superbolus Log app start to NS ns_logappstartedevent Exiting application to apply settings. DanaRv2 Insulin Fast Acting Insulin Novorapid, Novolog, Humalog Fiasp INS Fast Acting Insulin Prolonged key_usersuperbolus Enable superbolus in wizard Enable superbolus functionality in wizard. Do not enable until you learn what it really does. IT MAY CAUSE INSULIN OVERDOSE IF USED BLINDLY! IOB COB Firmware Last connection Bluetooth status About Missing SMS permission xDrip Status (watch) xDrip Statusline (watch) xds Show BGI Add BGI to status line No upload to NS All data sent to NS are dropped. AAPS is connected to NS but no change in NS is done ns_upload_only ns_noupload Basal Step Bolus Step ExtendedBolus TempTarget Cancel Extended Bolus Sensor age Canula age Insulin age hours Basal type Invalid profile !!! ProfileSwitch Pump battery age Pump Battery Change Alarm options nsalarm_urgent_high nsalarm_high nsalarm_low nsalarm_urgent_low nsalarm_staledata nsalarm_urgent_staledata nsalarm_staledatavalue nsalarm_urgent_staledatavalue Urgent high High Low Urgent low Stale data Urgent stale data Stale data threshold [min] Urgent stale data threshold [min] Interval for autosens [h] Amount of hours in the past for sensitivity detection (carbs absorption time is excluded) openapsama_autosens_period nsclient_localbroadcasts Pump OpenAPS Uploader Sensitivity detection SENS Sensitivity Oref0 Sensitivity AAPS Absorption settings absorption_maxtime absorption_cutoff Meal max absorption time [h] Time in hours where is expected all carbs from meal will be absorbed rangetodisplay Visualize extended bolus as % SAGE IAGE CAGE PBAGE OAPS UPLD BAS EXT Lock screen Lock By turning on Autosense feature remember to enter all eated carbs. Otherwise carbs deviations will be identified wrong as sensitivity change !! Sensitivity WeightedAverage OK Cancel Not all profiles loaded! Values not stored! Accu-Chek Combo COMBO Enable broadcasts to other apps (like xDrip). Enable local Broadcasts. ACTIVITY & FEEDBACK CARBS & BOLUS CGM & OPENAPS PUMP Basal value [U/h] Duration [min] OpenAPS SMB SMB use_smb use_uam Enable UAM Enable SMB Use Super Micro Boluses instead of temp basal for faster action Detection of Unannounced meals insulin_oref_peak IOB Curve Peak Time Peak Time [min] Free-Peak Oref Rapid-Acting Oref Ultra-Rapid Oref Custom insulin DIA of %f too short - using %f instead! Activate profile Date INVALID Waiting for pairing on pump Paring OK Paring timed out PAIRING danars_paring_key_ danars_address danars_name No device found so far Empty reservoir Blood sugar measurement alert Remaining insulin level DanaRS Dana Selected pump Pair new pump Bolus speed danars_bolusspeed Set basal step to 0.01 U/h Serial number wizard_include_cob wizard_include_trend_bg Percentage Time shift Default Temp-Targets eatingsoon duration eatingsoon target activity duration activity target hypo duration hypo target eatingsoon_duration eatingsoon_target activity_duration activity_target hypo_duration hypo_target Prime Getting extended bolus status Getting bolus status Getting temporary basal status Getting pump settings Getting pump time reuse Controls from Watch Set Temp-Targets and enter Treatments from the watch. Connection timed out Food g m h ]]> kJ En Pr Fat ]]> Waiting for bolus end. Remaining %d sec. Processing event Starting bolus delivery Command is executed right now Pump driver corrected Pump unreachable Missed BG readings raise_urgent_alarms_as_android_notification Use system notifications for alerts and notifications enable_pump_unreachable_alert enable_missed_bg_readings Local alerts Alert if no BG data is received Alert if pump is unreachable Pump unreachable threshold [min] pump_unreachable_threshold missed_bg_readings_threshold Urgent Alarm INFO bt_watchdog bt_watchdog_last Bluetooth BT Watchdog Switches off the phone\'s bluetooth for one second if no connection to the pump is possible. This may help on some phones where the bluetooth stack freezes. DexcomG5 App (patched) Upload BG data to NS dexcomg5_nsupload G5 upload settings Show detailed delta Show delta with one more decimal place 45 60 75 90 105 120 Max minutes of basal to limit SMB to Unsupported pump firmware Send BG data to xDrip+ dexcomg5_xdripupload In xDrip+ select 640g/Eversense data source NSClient BG Basal value replaced by minimal supported value BG calculation Bolus IOB calculation Basal IOB calculation Trend calculation Superbolus calculation Yes No Positive only Negative only COB calculation Temporary target calculation Loop enabled APS selected NSClient has write permission Closed mode enabled Maximal IOB set properly BG available from selected source Basal values not aligned to hours: %s Invalid profile: %s Programming pump for bolusing Refresh State Activity No connection for %d min %d%% (%d min remaining) %.1f %s (%s) Initializing Suspended due to error Suspended by user Running Cancelling TBR Setting TBR (%d%% / %d min) Bolusing (%.1f U) Refreshing Requested operation not supported by pump Unsafe usage: extended or multiwave boluses are active. Loop mode has been set to low-suspend only 6 hours. Only normal boluses are supported in loop mode Unsafe usage: the pump uses a different basal rate profile than the first. The loop has been disabled. Select the first profile on the pump and refresh. A bolus with the same amount was requested within the last two minutes. To prevent accidental double boluses and to guard against bugs this is disallowed. Now Reading pump history pump history Setting basal profile Pump cartridge level is low Pump battery is low The pump is showing the error E%d: %s Low Empty Normal Pump clock update needed Warning TBR CANCELLED warning was confirmed The pump could not be reached. No bolus was given Bolus delivery failed. It appears no bolus was delivered. To be sure, please check the pump to avoid a double bolus and then bolus again. To guard against bugs, boluses are not automatically retried. Only %.2f U of the requested bolus of %.2f U was delivered due to an error. Please check the pump to verify this and take appropriate actions. Delivering the bolus and verifying the pump\'s history failed, please check the pump and manually create a bolus record using the Careportal tab if a bolus was delivered. Recovering from connection loss Not enough insulin for bolus left in reservoir Extended bolus delivery error Insight Insight Pump Status Changed PUMP STOPPED Status Updated ago with Active TBR min left Log book Last Completed Action min remaining over total with upfront with Stay always connected Use Real TBR cancels Actually cancel a TBR (creates pump alarm) instead of setting 90% for 1 minute IDLE SYNCING BUSY SYNCED STARTUP needs Not connected to companion app! Companion app does not appear to be installed! Incompatible companion app, we need version Unknown Waiting for code confirmation Code rejected App binding Not authorized Incompatible second minute hour day week s %ds expires %s Keep-alive status Statistics Connect preemptively Automatically connect when AndroidAPS screens are opened, before any pump command is requested, to reduce connection delay Not recommended due to battery drain enableSMB_always enableSMB_with_COB enableSMB_with_temptarget enableSMB_after_carbs enableSMB_with_high_temptarget Enable SMB always Enable SMB always independently to boluses. Possible only with BG source with nice filtering of data like G5 Enable SMB after carbs Enable SMB for 6h after carbs, even with 0 COB. Possible only with BG source with nice filtering of data like G5 Enable SMB with COB Enable SMB when there is COB active. Enable SMB with temp targets Enable SMB when there is temp target active (eating soon, exercise) Enable SMB with high temp targets Enable SMB when there is high temp target active (exercise) Let temp basal run Mute Insulin Carbs Buttons show_calibration_button show_cgm_button show_carbs_button show_wizard_button show_insulin_button show_treatment_button Sends a calibration to xDrip+ or open G5 calibration dialog Opens xDrip+, back buttons returns to AAPS insulin_button_increment_1 insulin_button_increment_2 insulin_button_increment_3 carbs_button_increment_1 carbs_button_increment_2 carbs_button_increment_3 Number of carbs to add when button is pressed Amount of insulin to add when button is pressed Could not launch CGM application. Make sure it is installed. CGM History browser Notify on SMB Show SMB on the watch like a standard bolus. ns_create_announcements_from_errors Create announcements from errors Create Nightscout announcement for error dialogs and local alerts (also viewable in Careportal under Treatments) G5 Show the predictions on the watchface. Predictions Data Choices Fabric Upload Allow automated crash reporting and feature usage data to be sent to the developers via the fabric.io service. Please update your G5 app to supported version Start Activity TT Start Eating soon TT TT Do not bolus, record only Category Subcategory Bolus will be recorded only Autobackfill missig BGs from NS ns_autobackfill SMB set by pump Sensitivity Deviations Carbs On Board Insulin On Board Basals No action selected, nothing will happen Start Hypo TT Running dev version. Closed loop is disabled. fromNSAreCommingFakedExtendedBoluses Engineering mode enabled Engineering mode not enabled and not on release branch %.2f U/h Reading basal profile The pump history has changed after the bolus calculation was performed. The bolus was not delivered. Please recalculate if a bolus is still needed. If the same bolus amount is required, please wait two minutes since boluses with the same amount are blocked when requested with less than two minutes between them for safety (regardless of whether they were administered or not). Bolus successfully delivered, but adding the treatment entry failed. This can happen if two small boluses of the same size are administered within the last two minutes. Please check the pump history and treatment entries and use the Careportal to add missing entries. Make sure not to add any entries for the exact same minute and same amount. Rejecting high temp since calculation didn\'t consider recently changed pump history Refreshing pump state The basal rate on the pump has changed and will be updated soon Basal rate changed on pump, but reading it failed Checking for history changes Multiple boluses with the same amount within the same minute were just imported. Only one record could be added to treatments. Please check the pump and manually add a bolus record using the Careportal tab. Make sure to create a bolus with a time no other bolus uses. \n\nhttp://www.androidaps.org\nhttp://www.androidaps.de (de)\n\nfacebook:\nhttp://facebook.androidaps.org\nhttp://facebook.androidaps.de (de) The last bolus is older than 24 hours or is in the future. Please check the date on the pump is set correctly. Time/date of the delivered bolus on pump seems wrong, IOB is likely incorrect. Please check pump time/date. ProfileSwitch missing. Please do a profile switch or press \"Activate Profile\" in the LocalProfile. Bolus count TBR count Objective %d not started Objective %d not finished Pump is not temp basal capable No valid basal rate read from pump Closed loop mode disabled in preferences Autosens disabled in preferences SMB disabled in preferences Limiting max basal rate to %.2f U/h because of %s pump limit openapsma_max_basal openapsama_current_basal_safety_multiplier openapsama_max_daily_safety_multiplier it must be positive value max basal multiplier max daily basal multiplier openapsma_max_iob A bolus was delivered within the last 3 minutes, skipping SMB Basal set correctly Limiting max percent rate to %d%% because of %s treatmentssafety_maxbolus Limiting bolus to %.1f U because of %s Limiting max IOB to %.1f U because of %s Limiting carbs to %d g because of %s Limiting IOB to %.1f U because of %s max value in preferences hard limit treatmentssafety_maxcarbs unsafe usage openapsama_useautosens Read status failed Record pump site change Record insulin cartridge change SMB always and after carbs disabled because active BG source doesn\'t support advanced filtering SMB not allowed in open loop mode Food IobCobCalculator reset Waiting for time synchronization (%d sec) Disconnected (%d m) Automatic careportal events Automatically upload insulin, cannula and battery changes and pump alarms to Nightscout openapsmb_max_iob Maximum total IOB OpenAPS can\'t go over [U] This value is called Max IOB in OpenAPS context\nOpenAPS will not add more insulin if current IOB is greater than this value Pump stopped Pump started Pump paused Meal max absorption time [h] Time at which any meal is considered absorbed. Remaining carbs will be cut off. Time show_notes_entry_dialogs Show notes field in treatment dialogs SetupWizardActivity Next Prev Skip Setup Wizard Next Prev Skip FINISH Select your language language openapsama_min_5m_carbimpact Asked: %.2fU Delivered: %.2fU Error code: %d First insulin increment Second insulin increment Third insulin increment First carbs increment Second carbs increment Third carbs increment CGM ns_wifionly ns_wifi_ssids ns_allowroaming ns_chargingonly Use WiFi connection only WiFi SSID Only if charging Connection settings Allowed SSIDs (semicolon separated) Allow connection in roaming always_use_shortavg Max autosens ratio Min autosens ratio Bolus snooze dia divisor Max daily safety multiplier Current basal safety multiplier n/a Autobackfill BG Irish Wizard Settings wearwizard_bg wearwizard_tt wearwizard_trend wearwizard_cob wearwizard_bolusiob wearwizard_basaliob Calculations included in the Wizard result: Display Settings General Settings Enable NSClient Welcome to setup wizard. It will guide you through the setup process\n Pump setup Read status Changes must be done in NS Skip setup wizard Where should blood glucose(BG) data be comming from ?\n Press the button below to enable AndroidAPS to suggest/make basal changes Press the button below to enable Objectives. Look in the Objectives tab, after you finish this wizard, to make AndroidAPS completely functional.\n Enable Objectives Configure APS plugin Exported configuration is missing thus import configuration is not possible.\n startupwizard_processed Configure Sensitivity plugin Sensitivity plugin is used for sensitivity detection and COB calculation. For more info visit: https://github.com/MilosKozak/AndroidAPS/wiki/Sensitivity-detection-and-COB NSClient handles connection to Nightscout. You can skip this part now but you will not be able to pass objectives until you setup it. Please remember: new insulin profiles require DIA at least 5h. DIA 5-6h on new profile is equal to DIA 3h on old insulin profiles. Configure BG source Please select source of profile. If patient is a child you should use NS profile. If there is nobody following you on Nightscout you will probably prefer Local profile. Please remember that you are only selecting the profile source. To use it you must activate it by executing \"Profile switch\" Select one from availables algorithms. They are sorted from oldest to newest. Newer algorithm is usualy more powerfull and more aggresive. Thus if you are new looper you may probably start with AMA and not with latest one. Do not forget to read the OpenAPS documentation and configure it before use. Start your first objective Permission Ask for permission Application needs location permission for BT scan Application needs storage permission to be able store log files