English Czech Afrikaans Bulgarian Dutch French German Greek Chinese Italian Korean Lithuanian Polish Portuguese Portuguese, Brazilian Romanian Russian Slovak Spanish Swedish Turkish Treatments safety Max allowed bolus [U] Max allowed carbs [g] Preferences Refresh treatments from NS Reset Databases Do you really want to reset the databases? Exit Use extended boluses for >200%% DanaR Bluetooth device Always use basal absolute values Please reboot your phone or restart AndroidAPS from the System Settings \notherwise Android APS will not have logging (important to track and verify that the algorithms are working correctly)! This device does not appear to support battery optimization whitelisting - you may experience performance issues. Some buttons to quickly access common features Enter advanced log book entries. Used for configuring the active plugins Learning program Displays the food presets defined in Nightscout Insulin preset for Humalog and NovoRapid / NovoLog Insulin preset for Fiasp Allows you to define the peak of the insulin activity and should only be used by advanced users Activate or deactivate the implementation triggering the loop. Synchronizes your data with Nightscout State of the algorithm in 2016 State of the algorithm in 2017 Most recent algorithm for advanced users Displays the current state of your loop and buttons for most common actions Shows an ongoing notification with a short overview of what your loop is doing Define a profile which is available offline. Provides the profile you have defined in Nightscout Define a profile with only one time block. Pump integration for Accu-Chek Combo pumps, requires having ruffy installed Pump integration for DANA Diabecare R pumps Pump integration for domestic DANA Diabecare R pumps Pump integration for DANA Diabecare R pumps with upgraded firmware Pump integration for DANA Diabecare RS pumps Pump integration for people who do multiple daily injections for their diabetes therapy Pump integration for pumps which don\'t have any driver yet (Open Loop) Sensitivity is calculated the same way like Oref0, but you can specify timeframe to the past. Minimal carb absorption is calculated from max carb absorption time from preferences. Sensitivity is calculated from 24h data in the past and carbs (if not absorbed) are cut after time specified in preferences. Sensitivity is calculated from 8h data in the past and carbs (if not absorbed) are cut after time specified in preferences. Plugin also calculates UAM. Sensitivity is calculated as a weighted average from deviations. Newer deviations have higher weight. Minimal carb absorption is calculated from max carb absorption time from preferences. This algorithm is the fastest in following sensitivity changes. Receive BG values from the patched Eversense app. Receive BG values from Glimp. Receive BG values from the 600SeriesAndroidUploader. Downloads BG data from Nightscout Receive BG values from xDrip. Saves all treatments that were made Monitor and control AndroidAPS using your WearOS watch. Show information about your loop on your xDrip+ watchface. Remote control AndroidAPS using SMS commands. Units DIA IC ISF Basal Target NO PROFILE SET Insulin: Carbs: IOB: IOB: Total IOB: Total IOB activity: Dur: Ratio: Ins: IOB: Total IOB: Insulin Carbs BG TT Carbs Corr U Bolus IOB Run now VIRTUAL PUMP Base basal rate Temp basal Extended bolus Battery Reservoir OK Last run Input parameters Glucose status Current temp IOB data Profile Meal data Result Result: %1$s %2$s No glucose data available No change requested Request Rate Duration Reason Glucose Delta Delta: Config Builder Objectives OpenAPS MA Overview NS Profile Simple profile TempBasal Treatments Virtual Pump Careportal Pump Which pump would you like to use with AndroidAPS? Treatments Which plugin should be used for treatment handling? Profile Which profile should AndroidAPS use? APS Which APS algorithm should make therapy adjustments? General These are some general plugins you might find useful. Which constraints are applied? days Constraints Loop Loop Use this to activate AndroidAPS\' loop integration. APS After processed constraints Temp basal set by pump Last enacted OK Cancel NO APS SELECTED OR PROVIDED RESULT Safety Plugin is disabled Constraints violation Bolus delivery error Tempbasal delivery error Basal value [%%] %% (100%% = current) Accept new temp basal: Treatment Calculator Constraint applied! Confirmation Enter new treatment: Bolus Bolus: Basal Basal: Carbs Change your input! Set new extended bolus: BG Source Where should AndroidAPS gain it\'s data from? xDrip APS Mode Closed Loop Open Loop Loop Disabled Disable loop Enable loop New suggestion available Unsupported version of NSClient Unsupported version of Nightscout NSClient not installed. Record lost! LOOP DISABLED BY CONSTRAINTS Basal IOB Bolus constraint applied Carbs constraint applied BG Check Announcement Note Question Exercise Pump Site Change CGM Sensor Insert CGM Sensor Start Insulin Cartridge Change Profile Switch Snack Bolus Meal Bolus Correction Bolus Combo Bolus Temp Basal Start Temp Basal End Carbs correction OpenAPS Offline Event type Other Meter Sensor Carbs Insulin Carb time Split Duration Percent Absolute Notes Event time Profile Entered By Glucose type No profile loaded from NS yet TempBasal Extended Bolus Nightscout version: Missing %1$dg Preferences exported Export settings to Import settings from Settings imported File not found Export settings Import settings Max U/hr a Temp Basal can be set to This value is called max basal in OpenAPS context Maximum basal IOB OpenAPS can deliver [U] This value is called Max IOB in OpenAPS context\nThis is maximal insulin in [U] APS can deliver at once. DISMISS Language DanaR Connecting Connected Disconnected DanaR pump settings End User License Agreement MUST NOT BE USED TO MAKE MEDICAL DECISIONS. THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. I UNDERSTAND AND AGREE Save No bluetooth adapter found Selected device not found Pump connection error Pump IOB Daily units Last bolus %1$.1fh ago Invalid input data Value not set properly Reload profile View profile Enacted Comment Success Percent Absolute Cancel temp basal SMS Communicator Waiting for result Allowed phone numbers +XXXXXXXXXX;+YYYYYYYYYY To deliver bolus %1$.2fU reply with code %2$s To deliver meal bolus %1$.2fU reply with code %2$s To set the Temp Target %1$s reply with code %2$s To cancel Temp Target reply with code %1$s To disable the SMS Remote Service reply with code %1$s.\n\nKeep in mind that you\'ll able to reactivate it directly from the AAPS master smartphone only. SMS Remote Service stopped. To reactivate it, use AAPS on master smartphone. To send calibration %1$.2f reply with code %2$s Bolus failed smscommunicator_remotebolusmindistance Minimum number of minutes that must elapse between one remote bolus and the next How many minutes must elapse, at least, between one bolus and the next For your safety, to edit this preference you need to add at least 2 phone numbers. Bolus %1$.2fU delivered successfully Going to deliver %1$.2fU Bolus %1$.2fU delivered successfully Meal Bolus %1$.2fU delivered successfully Target %1$s for %2$d minutes Target %1$s for %2$d minutes set successfully Temp Target canceled successfully Delivering %1$.2fU Allow remote commands via SMS Finger Sensor Manual Temporary Target Temporary Target Cancel DanaR profile settings DIA [h] Duration of Insulin Activity Failed to update basal profile Reload Uploading E bolus DS bolus DE bolus error refill basal hour glucose carbohydrate alarm Total %1$d records uploaded S bolus Alarms Basal Hours Boluses Carbohydrates Daily insulin Errors Glucose Refill Suspend Connecting for %1$d s Pump password Wrong pump password! Pump is busy Delivered Stopped Bolus stopped Stopping bolus Occlusion Stop STOP PRESSED Waiting for pump Going to deliver %1$.2fU You reached allowed limit No profile selected Loop has been disabled Loop has been enabled Loop is disabled Loop is enabled %1$.2f limited to %2$.2f Value %1$s is out of hard limits Remote command is not allowed Remote bolus not available. Try again later. To start basal %1$.2fU/h for %2$d min reply with code %3$s To switch profile to %1$s %2$d%% reply with code %3$s To start extended bolus %1$.2fU for %2$d min reply with code %3$s To enter %1$dg at %2$s reply with code %3$s To start basal %1$d%% for %2$d min reply with code %3$s To suspend loop for %1$d minutes reply with code %2$s Temp basal %1$.2fU/h for %2$d min started successfully Extended bolus %1$.2fU for %2$d min started successfully Carbs %1$dg entered successfully Entering %1$dg of carbs failed Temp basal %1$d%% for %2$d min started successfully Temp basal start failed Extended bolus start failed To stop temp basal reply with code %1$s To stop extended bolus reply with code %1$s Temp basal canceled Extended bolus canceled Canceling temp basal failed Canceling extended bolus failed Unknown command or wrong reply QuickWizard QuickWizard settings Button text: Carbs: Valid: Add Edit Remove Meal Corr Actions AndroidAPS started NS upload only (disabled sync) NS upload only. Not effective on SGV unless a local source like xDrip is selected. Not effective on Profiles while NS-Profiles is used. Pump not initialized! Pump not initialized, profile not set! Prime/Fill Please make sure the amount matches the specification of your infusion set! Other Fill/Prime standard insulin amounts. Button 1 Button 2 Button 3 Units: mg/dl mmol/l DIA: Target range: Range for Visualization High and low mark for the charts in Overview and Smartwatch LOW mark HIGH mark Wear Resend All Data Open Settings on Wear Pump Error Low Battery Pump Shutdown Pump Battery Discharged DanaR Korean Basal rate: Setting of basal profile failed Basal profile in pump updated Disable EasyUI mode in pump Enable extended boluses on pump Change mode from U/d to U/h on pump Basal value below minimum. Profile not set! BG: Last BG: MDI MM640g Ongoing Notification OLD DATA %1$d min ago %1$dmin ago Local Profile OpenAPS AMA Short avg. delta Long avg. delta Array of %1$d elements.\nActual value: Autosens data Script debug Use Autosens feature Refresh events from NS Delete treatments in the future Eating Soon Hypo Activity Remove record: DanaR Stats Cumulative TDD Exponentially Weighted TDD Basal Bolus TDD Date Ratio # Days Weight Possibly inaccurate if using boluses for priming/filling! Old Data Please Press "RELOAD" Total Base Basal TBB * 2 Initializing ... ACT CONF LOOP SP OAPS LP DANA HOME VPUMP NSPROFILE TREAT CP OBJ WEAR SMS Shorten tab titles Always use short average delta instead of simple delta Useful when data from unfiltered sources like xDrip gets noisy. Advanced Settings key_advancedsettings Model: %1$02X Protocol: %2$02X Code: %3$02X Profile Default value: 3 This is a key OpenAPS safety cap. What this does is limit your basals to be 3x (in this people) your biggest basal rate. You likely will not need to change this, but you should be aware that’s what is discussed about “3x max daily; 4x current” for safety caps. Default value: 4 This is the other half of the key OpenAPS safety caps, and the other half of “3x max daily; 4x current” of the safety caps. This means your basal, regardless of max basal set on your pump, cannot be any higher than this number times the current level of your basal. This is to prevent people from getting into dangerous territory by setting excessively high max basals before understanding how the algorithm works. Again, the default is 4x; most people will never need to adjust this and are instead more likely to need to adjust other settings if they feel like they are “running into” this safety cap. autosens_max Default value: 1.2\nThis is a multiplier cap for autosens (and soon autotune) to set a 20%% max limit on how high the autosens ratio can be, which in turn determines how high autosens can adjust basals, how low it can adjust ISF, and how low it can set the BG target. autosens_min Default value: 0.7\nThe other side of the autosens safety limits, putting a cap on how low autosens can adjust basals, and how high it can adjust ISF and BG targets. autosens_adjust_targets Autosens adjust targets too Default value: true\nThis is used to allow autosens to adjust BG targets, in addition to ISF and basals. bolussnooze_dia_divisor Default value: 2\nBolus snooze is enacted after you do a meal bolus, so the loop won’t counteract with low temps when you’ve just eaten. The example here and default is 2; so a 3 hour DIA means that bolus snooze will be gradually phased out over 1.5 hours (3DIA/2). min_5m_carbimpact Default value: 3.0 (AMA) or 8.0 (SMB). This is a setting for default carb absorption impact per 5 minutes. The default is an expected 3mg/dl/5min. This affects how fast COB are decayed, and how much carb absorption is assumed in calculating future predicted BG, when BG is falling more than expected, or not rising as much as expected. Attention!\nNormally you do not have to change these values below. Please CLICK HERE and READ the text and make sure you UNDERSTAND it before change any of these values. http://openaps.readthedocs.io/en/latest/docs/walkthrough/phase-3/beyond-low-glucose-suspend.html Only numeric digits are allowed. Only numeric digits within the range %1$s - %2$s are allowed. The field must not be empty Phone number not valid Invalid SMS phone number Calibration Send calibration %1$.1f to xDrip? xDrip+ not installed Calibration sent to xDrip Calibration sent. Receiving must be enabled in xDrip. xDrip is not receiving calibrations Pump suspended Getting pump status Setting temp basal Stopping temp basal Setting extended bolus Stopping extended bolus Updating basal rates Disconnecting Executing Virtual pump settings Upload status to NS Wrong password Password for settings Unlock settings Approaching insulin daily limit NSClient NSCI URL: Autoscroll Restart NSClient Nightscout URL Enter Your Nightscout URL NS API secret NS API secret Enter NS API secret (min 12 chars) Deliver now Clear queue Show queue Queue: Status: Paused nsclientinternal_url nsclientinternal_api_secret danar_bt_name danar_password danar_useextended danar_visualizeextendedaspercentage" danarprofile_dia Clear log nsclientinternal_autoscroll nsclientinternal_paused NSCLIENT has no write permission. Wrong API secret? Wear settings Show detailed IOB Break down IOB into bolus and basal IOB on the watchface not successful - please check phone Not available smscommunicator_allowednumbers smscommunicator_remotecommandsallowed Patient age Child Teenage Adult Insulin resistant adult age child teenage adult resistantadult Please select patient age to setup safety limits I_understand Glimp %1$s needs battery optimalization whitelisting for proper performance Loop suspended Suspended (%1$d m) Superbolus (%1$d m) Suspend loop Suspend loop for 1h Suspend loop for 2h Suspend loop for 3h Suspend loop for 10 h Suspend loop for %1$d min Disconnect pump for 15 min Disconnect pump for 30 min Disconnect pump for 1 h Disconnect pump for 2 h Disconnect pump for 3 h Resume Reconnect Pump Wrong duration Loop suspended Loop resumed 15min trend COB Superbolus Log app start to NS ns_logappstartedevent Exiting application to apply settings. DanaRv2 Insulin Which type of insulin are you using? Fast Acting Insulin Novorapid, Novolog, Humalog Fiasp INS key_usersuperbolus Enable superbolus in wizard Enable superbolus functionality in wizard. Do not enable until you learn what it really does. IT MAY CAUSE INSULIN OVERDOSE IF USED BLINDLY! key_show_statuslights key_show_statuslights_extended Show status lights on home screen Show extended status lights on home screen Enable extended status lights for cage, iage, sage, reservoir and battery level on home screen. key_statuslights_res_warning Threshold warning reservoir level [U] key_statuslights_res_critical Threshold critical reservoir level [U] key_statuslights_bat_warning Threshold warning battery level [%] key_statuslights_bat_critical Threshold critical battery level [%] IOB COB Firmware Last connection Bluetooth status About Missing SMS permission Missing phone state permission xDrip Status (watch) xDrip Statusline (watch) xds Show BGI Add BGI to status line No upload to NS All data sent to NS are dropped. AAPS is connected to NS but no change in NS is done ns_upload_only ns_noupload Basal Step Bolus Step ExtendedBolus TempTarget Cancel Extended Bolus Sensor age Canula age Insulin age hours Basal type Invalid profile !!! ProfileSwitch Pump battery age Pump Battery Change Alarm options nsalarm_urgent_high nsalarm_high nsalarm_low nsalarm_urgent_low nsalarm_staledata nsalarm_urgent_staledata nsalarm_staledatavalue nsalarm_urgent_staledatavalue Urgent high High Low Urgent low Stale data Urgent stale data Stale data threshold [min] Urgent stale data threshold [min] Interval for autosens [h] Amount of hours in the past for sensitivity detection (carbs absorption time is excluded) openapsama_autosens_period nsclient_localbroadcasts Pump OpenAPS Uploader Sensitivity detection Which sensitivity algorithm should be used? SENS Sensitivity Oref0 Sensitivity Oref1 Sensitivity AAPS Absorption settings absorption_maxtime absorption_cutoff Meal max absorption time [h] Time in hours where is expected all carbs from meal will be absorbed rangetodisplay Visualize extended bolus as %% SAGE IAGE CAGE PBAGE OAPS UPLD BAS EXT Keep screen on Prevent Android to turn screen off. It will consume lot of energy when not plugged to power outlet. By turning on Autosense feature remember to enter all eated carbs. Otherwise carbs deviations will be identified wrong as sensitivity change !! Sensitivity WeightedAverage OK Cancel Not all profiles loaded! Values not stored! Accu-Chek Combo COMBO Enable broadcasts to other apps (like xDrip). Do not enable if you have more than one instance of AAPS or NSClient installed! Enable local Broadcasts. ACTIVITY & FEEDBACK CARBS & BOLUS CGM & OPENAPS PUMP Basal value [U/h] Duration [min] OpenAPS SMB SMB use_smb use_uam Enable UAM Enable SMB Use Super Micro Boluses instead of temp basal for faster action Detection of Unannounced meals insulin_oref_peak IOB Curve Peak Time Peak Time [min] Free-Peak Oref Rapid-Acting Oref Ultra-Rapid Oref DIA of %1$f too short - using %2$f instead! Activate profile Date INVALID Waiting for pairing on pump Pairing OK Pairing timed out PAIRING danars_pairing_key_ danars_address danars_name No device found so far Empty reservoir Blood sugar measurement alert Remaining insulin level DanaRS Dana Selected pump Pair new pump Bolus speed danars_bolusspeed Set basal step to 0.01 U/h Serial number wizard_include_cob wizard_include_trend_bg Percentage Time shift Default Temp-Targets eatingsoon duration eatingsoon target activity duration activity target hypo duration hypo target eatingsoon_duration eatingsoon_target activity_duration activity_target hypo_duration hypo_target Prime Getting extended bolus status Getting bolus status Getting temporary basal status Getting pump settings Getting pump time reuse Controls from Watch Set Temp-Targets and enter Treatments from the watch. Connection timed out Food g m h d ]]> kJ En Pr Fat ]]> Waiting for bolus end. Remaining %1$d sec. Processing event Starting bolus delivery Command is executed right now Pump driver corrected Pump unreachable Missed BG readings raise_urgent_alarms_as_android_notification Use system notifications for alerts and notifications enable_pump_unreachable_alert enable_missed_bg_readings Local alerts Alert if no BG data is received Alert if pump is unreachable Pump unreachable threshold [min] pump_unreachable_threshold missed_bg_readings_threshold Urgent Alarm INFO bt_watchdog bt_watchdog_last Bluetooth BT Watchdog Switches off the phone\'s bluetooth for one second if no connection to the pump is possible. This may help on some phones where the bluetooth stack freezes. Eversense App (patched) Upload BG data to NS dexcomg5_nsupload BG upload settings Show detailed delta Show delta with one more decimal place key_smbinterval How frequently SMBs will be given in min SMB max minutes Max minutes of basal to limit SMB to UAM SMB max minutes Max minutes of basal to limit SMB to for UAM carbsReqThreshold Carb suggestion threshold When Carbs are suggested, how many carbs will prompt a notification Unsupported pump firmware Send BG data to xDrip+ dexcomg5_xdripupload In xDrip+ select 640g/Eversense data source NSClient BG Basal value replaced by minimal supported value: %1$s Basal value replaced by maximum supported value: %1$s BG calculation Bolus IOB calculation Basal IOB calculation Trend calculation Superbolus calculation Yes No Positive only Negative only COB calculation Temporary target calculation Loop enabled APS selected NSClient has write permission Closed mode enabled Maximal IOB set properly BG available from selected source Basal values not aligned to hours: %1$s Invalid profile: %1$s Programming pump for bolusing Refresh State Activity No connection for %1$d min %1$d%% (%2$d min remaining) %1$.1f %2$s (%3$s) Initializing Suspended due to error Suspended by user Running Cancelling TBR Setting TBR (%1$d%% / %2$d min) Bolusing (%1$.1f U) Refreshing Requested operation not supported by pump Unsafe usage: extended or multiwave boluses are active. Loop mode has been set to low-suspend only 6 hours. Only normal boluses are supported in loop mode Unsafe usage: the pump uses a different basal rate profile than the first. The loop has been disabled. Select the first profile on the pump and refresh. A bolus with the same amount was requested within the last two minutes. To prevent accidental double boluses and to guard against bugs this is disallowed. Now Reading pump history pump history Setting basal profile Pump cartridge level is low Pump battery is low The pump is showing the error E%1$d: %2$s Low Empty Normal Pump clock update needed Warning TBR CANCELLED warning was confirmed The pump could not be reached. No bolus was given Bolus delivery failed. It appears no bolus was delivered. To be sure, please check the pump to avoid a double bolus and then bolus again. To guard against bugs, boluses are not automatically retried. Only %1$.2f U of the requested bolus of %2$.2f U was delivered due to an error. Please check the pump to verify this and take appropriate actions. Delivering the bolus and verifying the pump\'s history failed, please check the pump. If a bolus was delivered, it will be added to treatments during the next connection to the pump. Not enough insulin for bolus left in reservoir Extended bolus delivery error Sight ago %1$.2f h enableSMB_always enableSMB_with_COB enableSMB_with_temptarget enableSMB_after_carbs enableSMB_with_high_temptarget Enable SMB always Enable SMB always independently to boluses. Possible only with BG source with nice filtering of data like G5 Enable SMB after carbs Enable SMB for 6h after carbs, even with 0 COB. Possible only with BG source with nice filtering of data like G5 Enable SMB with COB Enable SMB when there is COB active. Enable SMB with temp targets Enable SMB when there is temp target active (eating soon, exercise) Enable SMB with high temp targets Enable SMB when there is high temp target active (exercise) Let temp basal run Mute Insulin Carbs Buttons show_calibration_button show_cgm_button show_carbs_button show_wizard_button show_insulin_button show_treatment_button Sends a calibration to xDrip+ or open G5 calibration dialog Opens xDrip+, back buttons returns to AAPS insulin_button_increment_1 insulin_button_increment_2 insulin_button_increment_3 carbs_button_increment_1 carbs_button_increment_2 carbs_button_increment_3 Number of carbs to add when button is pressed Amount of insulin to add when button is pressed Could not launch CGM application. Make sure it is installed. CGM History browser Notify on SMB Show SMB on the watch like a standard bolus. ns_create_announcements_from_errors Create announcements from errors Create Nightscout announcement for error dialogs and local alerts (also viewable in Careportal under Treatments) EVR Show the predictions on the watchface. Predictions Data Choices Fabric Upload Allow automated crash reporting and feature usage data to be sent to the developers via the fabric.io service. Please update your Dexcom app to supported version Dexcom app is not installed. Start Activity TT Start Eating soon TT TT Do not bolus, record only Category Subcategory Bolus will be recorded only Autobackfill missig BGs from NS ns_autobackfill SMB set by pump Activity Sensitivity Deviations Carbs On Board Insulin On Board Basals No action selected, nothing will happen Start Hypo TT Running dev version. Closed loop is disabled. fromNSAreCommingFakedExtendedBoluses Engineering mode enabled Engineering mode not enabled and not on release branch %1$.2f U/h Reading basal profile The pump history has changed after the bolus calculation was performed. The bolus was not delivered. Please recalculate if a bolus is still needed. Bolus successfully delivered, but adding the treatment entry failed. This can happen if two small boluses of the same size are administered within the last two minutes. Please check the pump history and treatment entries and use the Careportal to add missing entries. Make sure not to add any entries for the exact same minute and same amount. Rejecting high temp since calculation didn\'t consider recently changed pump history Refreshing pump state The basal rate on the pump has changed and will be updated soon Basal rate changed on pump, but reading it failed Checking for history changes Multiple boluses with the same amount within the same minute were just imported. Only one record could be added to treatments. Please check the pump and manually add a bolus record using the Careportal tab. Make sure to create a bolus with a time no other bolus uses. \n\nhttp://www.androidaps.org\nhttp://www.androidaps.de (de)\n\nfacebook:\nhttp://facebook.androidaps.org\nhttp://facebook.androidaps.de (de) The last bolus is older than 24 hours or is in the future. Please check the date on the pump is set correctly. Time/date of the delivered bolus on pump seems wrong, IOB is likely incorrect. Please check pump time/date. ProfileSwitch missing. Please do a profile switch or press \"Activate Profile\" in the LocalProfile. Bolus count TBR count Pump is not temp basal capable No valid basal rate read from pump Closed loop mode disabled in preferences Autosens disabled in preferences SMB disabled in preferences UAM disabled in preferences UAM disabled because it rely on Oref1 sensitivity plugin Limiting max basal rate to %1$.2f U/h because of %2$s pump limit openapsma_max_basal openapsama_current_basal_safety_multiplier openapsama_max_daily_safety_multiplier it must be positive value max basal multiplier max daily basal multiplier openapsma_max_iob A bolus was delivered within the last 3 minutes, skipping SMB Basal set correctly Limiting max percent rate to %1$d%% because of %2$s treatmentssafety_maxbolus Limiting bolus to %1$.1f U because of %2$s Limiting extended bolus to %1$.1f U because of %2$s Limiting max IOB to %1$.1f U because of %2$s Limiting carbs to %1$d g because of %2$s Limiting IOB to %1$.1f U because of %2$s max value in preferences hard limit treatmentssafety_maxcarbs unsafe usage openapsama_useautosens Read status failed Record pump site change Record insulin cartridge change SMB always and after carbs disabled because active BG source doesn\'t support advanced filtering SMB not allowed in open loop mode Food IobCobCalculator reset Waiting for time synchronization (%1$d sec) Disconnected (%1$d m) openapsmb_max_iob Maximum total IOB OpenAPS can\'t go over [U] This value is called Max IOB in OpenAPS context\nOpenAPS will not add more insulin if current IOB is greater than this value Pump stopped Pump started Pump paused Meal max absorption time [h] Time at which any meal is considered absorbed. Remaining carbs will be cut off. Time show_notes_entry_dialogs Show notes field in treatment dialogs SetupWizardActivity Next Prev Setup Wizard FINISH Select your language language openapsama_min_5m_carbimpact Asked: %1$.2fU Delivered: %2$.2fU Error code: %3$s First insulin increment Second insulin increment Third insulin increment First carbs increment Second carbs increment Third carbs increment CGM ns_wifionly ns_wifi_ssids ns_allowroaming ns_chargingonly Use WiFi connection only WiFi SSID Only if charging Connection settings Allowed SSIDs (semicolon separated) Allow connection in roaming always_use_shortavg Max autosens ratio Min autosens ratio Bolus snooze dia divisor Max daily safety multiplier Current basal safety multiplier n/a virtualpump_type Virtual Pump Type Pump Definition Bolus: Step=%1$s\nExtended Bolus: [Step=%2$s, Duration=%3$smin-%4$sh]\nBasal: Step=%5$s\nTBR: %6$s (by %7$s), Duration=%8$smin-%9$sh\n%10$s * Only discrete values no ranges are supported as granularity for basal/bolus in virtual pump. Autobackfill BG Wizard Settings wearwizard_bg wearwizard_tt wearwizard_trend wearwizard_cob wearwizard_bolusiob wearwizard_basaliob Calculations included in the Wizard result: Display Settings General Settings Enable NSClient Welcome to setup wizard. It will guide you through the setup process\n Pump setup Read status Changes must be done in NS Skip setup wizard Press the button below to enable AndroidAPS to suggest/make basal changes Configure APS plugin startupwizard_processed Configure Sensitivity plugin Sensitivity plugin is used for sensitivity detection and COB calculation. For more info visit: https://github.com/MilosKozak/AndroidAPS/wiki/Sensitivity-detection-and-COB NSClient handles connection to Nightscout. You can skip this part now but you will not be able to pass objectives until you set it up. Please remember: new insulin profiles require DIA at least 5h. DIA 5–6h on new profile is equal to DIA 3h on old insulin profiles. Configure BG source Please select source of profile. If patient is a child you should use NS profile. If there is nobody following you on Nightscout you will probably prefer Local profile. Please remember that you are only selecting the profile source. To use it you must activate it by executing \"Profile switch\" Select one from availables algorithms. They are sorted from oldest to newest. Newer algorithm is usually more powerful and more aggressive. Thus if you are new looper you may probably start with AMA and not with latest one. Do not forget to read the OpenAPS documentation and configure it before use. Start your first objective Permission Ask for permission Application needs location permission for BT scan Application needs storage permission to be able store log files Request Configure Insulin plugin Exit User options Display time format Button scroll Beep on button press Alarm Sound Vibrate Both LCD on time [s] Backlight on time [s] Glucose units Shutdown(hours) Low reservoir (Units) Save options to pump On Off Open navigation Close navigation Plugin preferences Completed, well done! Not completed yet Time elapsed Poctech Receive BG values from Poctech app Receive BG values from Tomato app (MiaoMiao device) high_temptarget_raises_sensitivity low_temptarget_lowers_sensitivity High temptarget raises sensitivity = 100]]> Low temptarget lowers sensitivity resistance_lowers_target Resistance lowers target When resistance is detected, lower the target glucose sensitivity_raises_target Sensitivity raises target When sensitivity is detected, raise the target glucose Invalid pump setup, check the docs and verify that the Quick Info menu is named QUICK INFO using the 360 configuration software. Custom Large Time Difference Large time difference:\nTime in pump is off by more than 1.5 hours.\nPlease adjust the time manually on the pump and make sure that reading the history from the pump does not cause unexpected behaviour.\nIf possible, remove the history from the pump before changing the time or disable the closed loop for one DIA after the last wrong history entry but minimum one DIA from now. keep_screen_on Clean AndroidAPS started Stored settings found Attention: If you activate and connect to a hardware pump, AndroidAPS will copy the basal settings from the profile to the pump, overwriting the existing basal rate stored on the pump. Make sure you have the correct basal setting in AndroidAPS. If you are not sure or don\'t want to overwrite the basal settings on your pump, press cancel and repeat switching to the pump at a later time. Treatment data incomplete Maintenance Settings Email maintenance_logs_email maintenance_logs_amount logshipper_amount No of Logs to send Maintenance MAINT Provides several functions for maintenance (eg. log sending, log deletion). Send Logs by Email Delete Logs A treatment (insulin: %1$.2f, carbs: %2$d, at: %3$s) could not be added to treatments. Please check and manually add a record as appropriate. eCarbs: %1$d g (%2$d h), delay: %3$d m No autosens data available Log settings Reset to defaults NSClient malfunction. Consider NS and NSClient restart. AS Version %1$s available Time offset aps_mode Preferred APS mode Total Calc Handshaking Send today\'s log files to developers along with this time. Unexpected situation. Max bolus violation Command error Speed error Insulin limit violation loop_openmode_min_change Minimal request change [%] Open Loop will popup new change request only if change is bigger than this value in %. Default value is 20% short_tabtitles Please pair your pump with your phone! Searching for devices… Please wait… Pairing completed Do the codes displayed on this device and on your pump match? Insight pairing Accu-Chek Insight %1$.2fU / %2$.2fU delivered %1$s: %2$s Tube changed Pump time updated Confirm Mute Pump alert Log site changes Log reservoir changes Log tube changes Log battery changes Log operating mode changes Log alerts Enable TBR emulation Use extended boluses instead of TBRs to bypass the 250%% limit Disconnect delay [s] Serial number Release software version UI processor software version PC processor software version MD tel processor software version Safety processor software version BT info page version Bluetooth address System ID appendix Manufacturing date Delete pairing Pairing information Start pump Stop pump Operating mode Status TDD Bolus TDD Basal TDD Total Recovering Not paired Last connected Started Stopped %1$d%% for %2$d / %3$d min Extended bolus Multiwave bolus %1$.2f / %2$.2f U for %3$d min Enable notification of TBR end\n(pump setting) Disable notification of TBR end\n(pump setting) Refresh Pump integration for Accu-Chek Insight pumps Not inserted Last conn: %1$d min ago TBR: %1$d%% for %2$d / %3$d min Extended: %1$.2f / %2$.2f U for %3$d min Multiwave: %1$.2f / %2$.2f U for %3$d min TDD: %1$.2f Reser.: %1$.2fU Batt.: %1$d%% Max. recovery duration [s] Min. recovery duration [s] Recovery duration Timeout during handshake - reset bluetooth Sun Sat Fri Thu Wed Tue Mon User defined automation tasks Please enter a task name. Please specify at least one trigger. Please specify at least one action. Already enabled Already disabled Already suspended Resume loop Not suspended Start temp target Stop temp target is lesser than is equal or lesser than is equal to is equal or greater than is greater than is not available unknown Glucose is not available Glucose %1$s %2$.0f %3$s Glucose %1$s %2$.1f %3$s Profile pct %1$s %2$d IOB %1$s %2$.1f And Or Exclusive or At %1$s Use network location Use GPS location Use passive location Location service location Auto Automation == ∑ %1$s U U/h g/U /U dexcom_lognssensorchange Log sensor change to NS Create event \"Sensor Change\" in NS automaticaly on sensor start Tomato (MiaoMiao) Tomato second minute hour day week seconds minutes hours days weeks tidepool_username tidepool_password tidepool_dev_servers tidepool_test_login tidepool_only_while_charging tidepool_only_while_unmetered Your Tidepool login user name, normally your email address Login User Name Your Tidepool login password Login Password Test Tidepool Login If enabled, uploads will go to https://int-app.tidepool.org instead of the regular https://app.tidepool.org/ Use Integration (test) servers Tidepool TDP Uploads data to Tidepool tidepool_last_end Upload CGM data tidepool_upload_cgm tidepool_upload_bolus Upload treatments (insulin, carbs) tidepool_upload_tbr Upload temporary basals tidepool_upload_profile Upload profile switches, temp targets tidepool_upload_bg Upload BG tests smbmaxminutes uamsmbmaxminutes Daylight Saving time Daylight Saving time change in 24h or less Daylight Saving time change less than 3 hours ago - Closed loop disabled internal storage constraint Free at least %1$d MB from internal storage! Loop disabled! Wrong format Wrong code. Command cancelled. Not configured Profile switch created Recurring time Every Never %1$dmins Condition: Action: IOB [U]: Glucose [%1$s]: DEL ADD COPY Add new Version Checker last_time_this_version_detected last_versionchecker_waring last_versionchecker_plugin_waring last_revoked_certs_check Signature verifier We have detected that you are running an invalid version. Loop disabled! old version very old version New version for at least %1$d days available! Fallback to LGS after 60 days, loop will be disabled after 90 days 2h %1$.2fU Dexcom App (patched) DXCM Receive BG values from the patched Dexcom app. Notification Notification: %1$s Msg: Profile percentage Percent [%]: Start profile %1$d%% for %2$d min Start profile %1$d%% exists not exists Temp target %1$s WiFi SSID %1$s %2$s Autosens %1$s %2$s %% Autosens % %3$s %1$s %2$s BG difference BG difference [%1$s] Current Location Location Lat: Lon: Dist [m]: Name: Location is %1$s Last bolus ago Last bolus time %1$s %2$s min ago COB COB %1$s %2$.0f Task name EDIT Please choose an action type: Please choose a trigger type: Triggers: REMOVE Preconditions: Operation not supported by pump and/or driver. Operation not YET supported by pump. Medtronic MDT Pump integration for Medtronic, requires RileyLink device and specific Pump Model pref_medtronic_serial pref_medtronic_pump_type pref_medtronic_frequency pref_medtronic_max_bolus pref_medtronic_max_basal pref_medtronic_bolus_delay pref_medtronic_encoding pref_medtronic_battery_type pref_medtronic_bolus_debug pref_rileylink_mac_address medtronic_pump_frequency_us_ca medtronic_pump_frequency_worldwide medtronic_pump_encoding_4b6b_local medtronic_pump_encoding_4b6b_rileylink medtronic_pump_battery_no medtronic_pump_battery_alkaline medtronic_pump_battery_lithium medtronic_pump_battery_nizn Pump Serial Number Pump Type Pump Frequency Delay before Bolus is started (s) Max Bolus on Pump (U) Max Basal on Pump (U/h) Medtronic Encoding US & Canada (916 MHz) Worldwide (868 Mhz) Software 4b6b Encoding Hardware 4b6b Encoding Wake and Tune Up Clear Bolus Block Reset RileyLink Config Battery Type (Power View) Not selected (Simple view) Alkaline (Extended view) Lithium (Extended view) NiZn (Extended view) Bolus/Treatments Debugging SCAN STOP Selected RileyLink Scan Bluetooth Low Energy not supported. Bluetooth not enabled. Location Is Not Enabled For Bluetooth discovery to work on newer devices, location must be enabled. AAPS does not track your location and it can be disabled after pairing is successful. Enable No Scanning Scanning finished Scanning error: %1$d Settings History RileyLink Status Pump Status RileyLink Settings RileyLink Configured Address Connected Device Connection Status Connection Error Device Device Type Device Model Last used frequency Last device contact RL Firmware Bluetooth Initializing… Bluetooth Error Bluetooth Ready Not Started RileyLink Initialization… RileyLink Error Tuning up RileyLink and Pump Problem connecting to Pump Connected Device is not RileyLink RileyLink unreachable Bluetooth disabled No Bluetooth Adapter TuneUp Failed Pump unreachable Pod unreachable Not set Medtronic Pump Omnipod Errors Serial # not set. Serial # invalid. Pump Type not set. Pump Type unsupported. Pump Frequency not set. Pump Frequency unsupported. RileyLink Address invalid. Pump type detected is not the same as configured type. Basal profiles are not enabled on pump. Basal profile set on pump is incorrect (must be STD). Wrong TBR type set on pump (must be Absolute). Wrong Max Bolus set on Pump (must be %1$.2f). Wrong Max Basal set on Pump (must be %1$.2f). Operation is not possible.\n\n You need to configure Medtronic Pump first, before you can use this operation. Over 24h Time change was requested. Basals Configurations Notifications Statistics Unknowns All Medtronic Pump History Never contacted Waking up Error with communication Timeout on communication Pump unreachable Invalid configuration Active Sleeping You cancelled Bolus, after it was already set on Pump. Since Medtronic Pump doesn\'t support cancel, you will need to manually cancel it. Put the Pump into Suspend mode and then do Resume (if you still want to cancel). Application will pick up changes, on next update (in less than 5 minutes). Could not read current TBR. Could not cancel current TBR. Stopping operation. Profile set failed, because following patterns, have too big basal rate: %1$s Bolus could not be delivered. Bolus could not be delivered, because available insulin amount (%1$.2f) is less than bolus required (%2$.2f). TBR could not be set. Could not cancel current TBR. Basal profile could not be set. Basal profile is the same, so it will not be set again. Get History - Page %1$d (%2$d/16) Get History - Page %1$d Get Pump Time Get Settings Get Pump Model Get Basal Profile Set Basal Profile Get Temporary Basal Set Temporary Basal Set Bolus Change profile to Change profile to %1$s Last connection to pump Last connection to pump [minutes ago] Last connection to pump %1$s %2$s min ago Send SMS: %1$s Send SMS to all numbers in preferences Send SMS with text %2$+.2fU]]> Bolus constraint applied: %2$.2fU to %3$.2fU]]> !!!!! Slow carbs absorption detected: %2$d%% of time. Double check your calculation. COB can be overestimated thus more insulin could be given !!!!!]]> %1$.0f / %2$d U boluswizard_percentage Deliver this part of bolus wizard result [%] Bolus wizard performs calculation but only this part of calculated insulin is delivered. Useful with SMB algorithm. Loading ... Snooze Time range Time is between %1$s and %2$s Between Close Increasing max basal value because setting is lower than your max basal in profile Invalid message body %1$s ISF: %2$.1f %1$.0fg IC: %2$.1f %1$.1fg IC: %2$.1f %1$d%% Bolus wizard min wizard_calculation_visible %1$dg On Off