Update instructions.
This commit is contained in:
parent
f903b83315
commit
e4454be5c1
1 changed files with 3 additions and 1 deletions
|
@ -38,10 +38,12 @@ How to use:
|
|||
- There are no warnings regarding low cartridge/battery since we're not reading that data from the pump just yet (next version)
|
||||
- Ensure you set the basal rate on the pump to the values of the profile used in AAPS, the profile isn't synced to the pump yet! Also don't forget to set/create a profile in AAPS **and** trigger a profile switch afterwards to activate it.
|
||||
- Don't press any buttons while commands are running (BT logo is displayed on pump display), or the command will fail
|
||||
- Let the ruffy app run in the background, don't interact with it, esp. not while AndroidAPS is issuning commands to the pump.
|
||||
- Let the ruffy app run in the background, don't interact with it, esp. not while AAPS is issuing commands to the pump.
|
||||
- To change cartridge: stop the loop, wait for AAPS to cancel any running TBR (check Combo tab), suspend/stop the pump, change cartridge, start the pump again and re-enable the loop. To enable/disable the loop, long press on the "Closed loop" label on the home screen (try long pressing all items next to it too ...).
|
||||
- AAPS guides first time users through objectives (tab must be set visible in config first, it's enabled irregardless of visibility). This ensures users learn to use AndroidAPS step by step as more and more advanced options are enabled.
|
||||
- If a running TBR was cancelled on the pump or through the pump: press _Cancel TBR_ in in AAPS, so AAPS knows about this as well. AAPS will issue a _cancel TBR command_ to the pump, which the pump will ignore. AAPS will set a new TBR the next time the loop runs or is manually triggered.
|
||||
- While all errors are reported, dealing with errors does not yet cover all cases. So after an error, the pump might be running a different TBR than what AAPS thinks the pump does.
|
||||
Issue a TBR Cancel in AAPS to get them lined up. In case of boluses, check the pump to be sure (press check twice to enter the bolus history menu).
|
||||
- Update this page if something is unclear or missing
|
||||
|
||||
Testing:
|
||||
|
|
Loading…
Reference in a new issue