Disable loop if unsupported basal rate profile is selected. Fixes #31.
This commit is contained in:
parent
c84ba24c77
commit
6af28479d6
|
@ -85,6 +85,8 @@ Usage:
|
|||
- The integration of the Combo with AndroidAPS is designed with the assumption that all inputs are
|
||||
made via AndroidAPS. Boluses entered on the pump will NOT be detected by AAPS and may therefore
|
||||
result in too much insulin being delivered.
|
||||
- The pump's first basal rate profile is read on app start and is updated by AAPS. Manually changing
|
||||
the pump's basal rate profile will lead to wrong basals being delivered and is NOT supported.
|
||||
- It's recommended to enable key lock on the pump to prevent bolusing from the pump, esp. when the
|
||||
pump was used before and quick bolusing was a habit.
|
||||
Also, with keylock enabled, accidentally pressing a key will NOT interrupt a running command
|
||||
|
|
|
@ -351,14 +351,22 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
|
||||
// read basal profile into cache and update pump profile if needed
|
||||
if (!pump.initialized) {
|
||||
if (stateResult.state.unsafeUsageDetected == PumpState.UNSUPPORTED_BASAL_RATE_PROFILE) {
|
||||
Notification n = new Notification(Notification.COMBO_PUMP_ALARM,
|
||||
MainApp.sResources.getString(R.string.combo_force_disabled_notification),
|
||||
Notification.URGENT);
|
||||
n.soundId = R.raw.alarm;
|
||||
MainApp.bus().post(new EventNewNotification(n));
|
||||
violationWarningRaisedForViolationAt = lowSuspendOnlyLoopEnforcedUntil;
|
||||
return;
|
||||
}
|
||||
CommandResult readBasalResult = runCommand("Reading basal profile", 2, ruffyScripter::readBasalProfile);
|
||||
if (!readBasalResult.success) {
|
||||
return;
|
||||
}
|
||||
pump.basalProfile = readBasalResult.basalProfile;
|
||||
}
|
||||
validBasalRateProfileSelectedOnPump = true;
|
||||
|
||||
if (!pump.initialized) {
|
||||
pump.initialized = true;
|
||||
MainApp.bus().post(new EventInitializationChanged());
|
||||
}
|
||||
|
@ -716,9 +724,7 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
|
||||
if (commandResult.success) {
|
||||
pump.lastSuccessfulCmdTime = System.currentTimeMillis();
|
||||
}
|
||||
|
||||
if (commandResult.success) {
|
||||
validBasalRateProfileSelectedOnPump = commandResult.state.unsafeUsageDetected != PumpState.UNSUPPORTED_BASAL_RATE_PROFILE;
|
||||
updateLocalData(commandResult);
|
||||
}
|
||||
} finally {
|
||||
|
@ -811,7 +817,7 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
if (commandResult == null) return;
|
||||
|
||||
long lastViolation = 0;
|
||||
if (commandResult.state.unsafeUsageDetected) {
|
||||
if (commandResult.state.unsafeUsageDetected == PumpState.UNSUPPORTED_BOLUS_TYPE) {
|
||||
lastViolation = System.currentTimeMillis();
|
||||
} else if (commandResult.lastBolus != null && !commandResult.lastBolus.isValid) {
|
||||
lastViolation = commandResult.lastBolus.timestamp;
|
||||
|
@ -823,14 +829,14 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
}
|
||||
}
|
||||
if (lastViolation > 0) {
|
||||
lowSuspendOnlyLoopEnforcetTill = lastViolation + 6 * 60 * 60 * 1000;
|
||||
if (lowSuspendOnlyLoopEnforcetTill > System.currentTimeMillis() && violationWarningRaisedFor != lowSuspendOnlyLoopEnforcetTill) {
|
||||
lowSuspendOnlyLoopEnforcedUntil = lastViolation + 6 * 60 * 60 * 1000;
|
||||
if (lowSuspendOnlyLoopEnforcedUntil > System.currentTimeMillis() && violationWarningRaisedForViolationAt != lowSuspendOnlyLoopEnforcedUntil) {
|
||||
Notification n = new Notification(Notification.COMBO_PUMP_ALARM,
|
||||
MainApp.sResources.getString(R.string.combo_force_disabled_notification),
|
||||
MainApp.sResources.getString(R.string.combo_low_suspend_forced_notification),
|
||||
Notification.URGENT);
|
||||
n.soundId = R.raw.alarm;
|
||||
MainApp.bus().post(new EventNewNotification(n));
|
||||
violationWarningRaisedFor = lowSuspendOnlyLoopEnforcetTill;
|
||||
violationWarningRaisedForViolationAt = lowSuspendOnlyLoopEnforcedUntil;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
@ -1058,8 +1064,9 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
}
|
||||
|
||||
// Constraints interface
|
||||
private long lowSuspendOnlyLoopEnforcetTill = 0;
|
||||
private long violationWarningRaisedFor = 0;
|
||||
private long lowSuspendOnlyLoopEnforcedUntil = 0;
|
||||
private long violationWarningRaisedForViolationAt = 0;
|
||||
private boolean validBasalRateProfileSelectedOnPump = false;
|
||||
|
||||
@Override
|
||||
public boolean isLoopEnabled() {
|
||||
|
@ -1068,7 +1075,7 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
|
||||
@Override
|
||||
public boolean isClosedModeEnabled() {
|
||||
return true;
|
||||
return validBasalRateProfileSelectedOnPump;
|
||||
}
|
||||
|
||||
@Override
|
||||
|
@ -1103,6 +1110,6 @@ public class ComboPlugin implements PluginBase, PumpInterface, ConstraintsInterf
|
|||
|
||||
@Override
|
||||
public Double applyMaxIOBConstraints(Double maxIob) {
|
||||
return lowSuspendOnlyLoopEnforcetTill < System.currentTimeMillis() ? maxIob : 0;
|
||||
return lowSuspendOnlyLoopEnforcedUntil < System.currentTimeMillis() ? maxIob : 0;
|
||||
}
|
||||
}
|
||||
|
|
|
@ -816,7 +816,8 @@
|
|||
<string name="raise_urgent_alarms_as_android_notification">Use system notifications for alerts</string>
|
||||
<string name="combo_pump_never_connected">Never</string>
|
||||
<string name="combo_pump_unsupported_operation">Requested operation not supported by pump</string>
|
||||
<string name="combo_force_disabled_notification">Unsafe usage: extended or multiwave boluses have been delivered within the last 6 hours or the selected basal rate is not 1. Loop mode has been set to low-suspend only until 6 hours after the last unsupported bolus or basal rate profile. Only normal boluses are supported in loop mode with basal rate profile 1.</string>
|
||||
<string name="combo_low_suspend_forced_notification">Unsafe usage: extended or multiwave boluses are active. Loop mode has been set to low-suspend only 6 hours. Only normal boluses are supported in loop mode</string>
|
||||
<string name="combo_force_disabled_notification">Unsafe usage: the pump uses a different basal rate profile than the first, which is not supported. Select the first profile on the pump and refresh.</string>
|
||||
<string name="bolus_frequency_exceeded">A bolus with the same amount was requested within the last minute. To prevent accidental double boluses and to guard against bugs this is disallowed.</string>
|
||||
<string name="combo_pump_connected_now">Now</string>
|
||||
<string name="combo_activity_reading_pump_history">Reading pump history</string>
|
||||
|
|
|
@ -30,8 +30,12 @@ public class PumpState {
|
|||
public int insulinState = UNKNOWN;
|
||||
|
||||
public int activeBasalProfileNumber;
|
||||
|
||||
public static final int SAFE_USAGE = 0;
|
||||
public static final int UNSUPPORTED_BOLUS_TYPE = 1;
|
||||
public static final int UNSUPPORTED_BASAL_RATE_PROFILE = 2;
|
||||
/** True if use of an extended or multiwave bolus has been detected */
|
||||
public boolean unsafeUsageDetected;
|
||||
public int unsafeUsageDetected = SAFE_USAGE;
|
||||
|
||||
public PumpState menu(String menu) {
|
||||
this.menu = menu;
|
||||
|
|
|
@ -501,8 +501,10 @@ public class RuffyScripter implements RuffyCommands {
|
|||
BolusType bolusType = (BolusType) menu.getAttribute(MenuAttribute.BOLUS_TYPE);
|
||||
Integer activeBasalRate = (Integer) menu.getAttribute(MenuAttribute.BASAL_SELECTED);
|
||||
|
||||
if (bolusType != null && bolusType != BolusType.NORMAL || !activeBasalRate.equals(1)) {
|
||||
state.unsafeUsageDetected = true;
|
||||
if (!activeBasalRate.equals(1)) {
|
||||
state.unsafeUsageDetected = PumpState.UNSUPPORTED_BASAL_RATE_PROFILE;
|
||||
} else if (bolusType != null && bolusType != BolusType.NORMAL) {
|
||||
state.unsafeUsageDetected = PumpState.UNSUPPORTED_BOLUS_TYPE;
|
||||
} else if (tbrPercentage != null && tbrPercentage != 100) {
|
||||
state.tbrActive = true;
|
||||
Double displayedTbr = (Double) menu.getAttribute(MenuAttribute.TBR);
|
||||
|
|
|
@ -10,6 +10,7 @@ import org.slf4j.LoggerFactory;
|
|||
import java.util.Arrays;
|
||||
|
||||
import de.jotomo.ruffy.spi.BasalProfile;
|
||||
import de.jotomo.ruffy.spi.PumpState;
|
||||
|
||||
public class ReadBasalProfileCommand extends BaseCommand {
|
||||
private static final Logger log = LoggerFactory.getLogger(ReadBasalProfileCommand.class);
|
||||
|
@ -17,6 +18,9 @@ public class ReadBasalProfileCommand extends BaseCommand {
|
|||
@Override
|
||||
public void execute() {
|
||||
scripter.verifyMenuIsDisplayed(MenuType.MAIN_MENU);
|
||||
if (scripter.readPumpStateInternal().unsafeUsageDetected == PumpState.UNSUPPORTED_BASAL_RATE_PROFILE) {
|
||||
throw new CommandException("Active basal rate profile != 1");
|
||||
}
|
||||
scripter.navigateToMenu(MenuType.BASAL_1_MENU);
|
||||
scripter.verifyMenuIsDisplayed(MenuType.BASAL_1_MENU);
|
||||
scripter.pressCheckKey();
|
||||
|
|