MDT: fix notificaion call
This commit is contained in:
parent
36bbb0754c
commit
009cec2eb1
|
@ -343,7 +343,7 @@ class MedtronicPumpPlugin @Inject constructor(
|
|||
var resetTime = false
|
||||
if (isPumpNotReachable) {
|
||||
aapsLogger.error("Pump unreachable.")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpUnreachable, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpUnreachable, rh)
|
||||
return
|
||||
}
|
||||
medtronicUtil.dismissNotification(MedtronicNotificationType.PumpUnreachable, rxBus)
|
||||
|
@ -413,7 +413,7 @@ class MedtronicPumpPlugin @Inject constructor(
|
|||
if (isRefresh) {
|
||||
if (isPumpNotReachable) {
|
||||
aapsLogger.error(logPrefix + "initializePump::Pump unreachable.")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpUnreachable, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpUnreachable, rh)
|
||||
setRefreshButtonEnabled(true)
|
||||
return true
|
||||
}
|
||||
|
@ -426,7 +426,7 @@ class MedtronicPumpPlugin @Inject constructor(
|
|||
} else {
|
||||
if (medtronicPumpStatus.medtronicDeviceType !== medtronicUtil.medtronicPumpModel) {
|
||||
aapsLogger.warn(LTag.PUMP, logPrefix + "Configured pump is not the same as one detected.")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpTypeNotSame, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpTypeNotSame, rh)
|
||||
}
|
||||
}
|
||||
pumpState = PumpDriverState.Connected
|
||||
|
@ -578,7 +578,7 @@ class MedtronicPumpPlugin @Inject constructor(
|
|||
} else {
|
||||
if (clock.localDeviceTime.year > 2015) {
|
||||
aapsLogger.error(String.format(Locale.ENGLISH, "MedtronicPumpPlugin::checkTimeAndOptionallySetTime - Time difference over 24h requested [diff=%d s]. Doing nothing.", timeDiff))
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.TimeChangeOver24h, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.TimeChangeOver24h, rh)
|
||||
}
|
||||
}
|
||||
} else {
|
||||
|
|
|
@ -115,7 +115,7 @@ class MedtronicUIPostprocessor @Inject constructor(
|
|||
MedtronicCommandType.PumpModel -> {
|
||||
if (medtronicPumpStatus.medtronicDeviceType !== medtronicUtil.medtronicPumpModel) {
|
||||
aapsLogger.warn(LTag.PUMP, "Configured pump is different then pump detected !")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpTypeNotSame, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpTypeNotSame, rh)
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -156,12 +156,12 @@ class MedtronicUIPostprocessor @Inject constructor(
|
|||
checkValue = settings["PCFG_BASAL_PROFILES_ENABLED"]!!
|
||||
if ("Yes" != checkValue.value) {
|
||||
aapsLogger.error(LTag.PUMP, "Basal profiles are not enabled on pump.")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpBasalProfilesNotEnabled, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpBasalProfilesNotEnabled, rh)
|
||||
} else {
|
||||
checkValue = settings["PCFG_ACTIVE_BASAL_PROFILE"]!!
|
||||
if ("STD" != checkValue.value) {
|
||||
aapsLogger.error("Basal profile set on pump is incorrect (must be STD).")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpIncorrectBasalProfileSelected, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpIncorrectBasalProfileSelected, rh)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
@ -170,7 +170,7 @@ class MedtronicUIPostprocessor @Inject constructor(
|
|||
if (settings.containsKey("PCFG_TEMP_BASAL_TYPE")) {
|
||||
if ("Units" != settings["PCFG_TEMP_BASAL_TYPE"]!!.value) {
|
||||
aapsLogger.error("Wrong TBR type set on pump (must be Absolute).")
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongTBRTypeSet, rh, rxBus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongTBRTypeSet, rh)
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -179,7 +179,7 @@ class MedtronicUIPostprocessor @Inject constructor(
|
|||
checkValue = settings["PCFG_MAX_BOLUS"]!!
|
||||
if (!MedtronicUtil.isSame(checkValue.value.toDouble(), medtronicPumpStatus.maxBolus!!)) {
|
||||
aapsLogger.error(LTag.PUMPCOMM, String.format(Locale.ENGLISH, "Wrong Max Bolus set on Pump (current=%s, required=%.2f).", checkValue.value, medtronicPumpStatus.maxBolus))
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongMaxBolusSet, rh, rxBus, medtronicPumpStatus.maxBolus)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongMaxBolusSet, rh, medtronicPumpStatus.maxBolus)
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -187,7 +187,7 @@ class MedtronicUIPostprocessor @Inject constructor(
|
|||
checkValue = settings["PCFG_MAX_BASAL"]!!
|
||||
if (!MedtronicUtil.isSame(checkValue.value.toDouble(), medtronicPumpStatus.maxBasal!!)) {
|
||||
aapsLogger.error(LTag.PUMPCOMM, String.format(Locale.ENGLISH, "Wrong Max Basal set on Pump (current=%s, required=%.2f).", checkValue.value, medtronicPumpStatus.maxBasal))
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongMaxBasalSet, rh, rxBus, medtronicPumpStatus.maxBasal)
|
||||
medtronicUtil.sendNotification(MedtronicNotificationType.PumpWrongMaxBasalSet, rh, medtronicPumpStatus.maxBasal)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
|